Real-time three-dimensional echocardiographic left ventricular systolic assessment: side-by-side comparison with 64-slice multi-detector cardiac computed tomography.

نویسندگان

  • Marcelo L C Vieira
  • César H Nomura
  • Bernardino Tranchesi
  • Wercules A de Oliveira
  • Gustavo Naccarato
  • Bruna S Serpa
  • Rodrigo B D Passos
  • Marcelo B G Funari
  • Cláudio H Fischer
  • Samira S Morhy
چکیده

AIMS To investigate by real-time 3D echocardiography (RT3DE) and cardiac computed tomography (CCT) the analysis of left ventricle ejection fraction (LVEF) and volumes. METHODS AND RESULTS A total of 67 patients (37 males, 55 +/- 11 years) were studied prospectively by RT3DE and by 64-slice CCT. RT3DE data: LVEF ranged from 30 to 78.6% (63.1 +/- 7.33); left ventricular end-diastolic volume (LVEDV) from 44.1 to 210 (104.9 +/- 29.7) mL; left ventricular end-systolic volume (LVESV) from 11.4 to 149 ( 38.9 +/- 19.3) mL. CCT data: LVEF ranged from 28 to 86% (66 +/- 8.4); LVEDV from 51 to 212 (110.3 +/- 31.2) mL; LVESV from 7 to 152 (38.2 +/- 19.2) mL. Correlations relative to RT3DE and CCT were: LVEF (r: 0.79, P < 0.0001); LVEDV (r: 0.82, P < 0.0001); and LVESV (r: 0.91, P < 0.0001). CONCLUSION It was observed adequate correlation between RT3DE and CCT ventricular systolic function and geometry assessment.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of global and regional left ventricular function and volumes with 64-slice multi-slice computed tomography: a comparison with 2D echocardiography

Introduction: In patients with coronary artery disease (CAD), LV function and volumes are important parameters for long-term prognosis. 64-slice MSCT allows non-invasive assessment of the coronary arteries, but the accuracy of 64-slice MSCT for assessment of LV volumes and function is unknown. Methods: A head-to-head comparison between 64-slice MSCT and 2D echocardiography was performed in 40 p...

متن کامل

Feasibility of Real-Time Three-Dimensional Echocardiography for the Assessment of Distorted Biventricular Systolic Function in Patients with Cor Pulmonale

BACKGROUND This study was to investigate the feasibility of real-time 3-dimensional echocardiography (RT3DE) for the analysis of biventricular ejection fractions and volume measurements in patients with cor pulmonale and the correlations of RT3DE results with 64-slice multi-detector cardiac computed tomography (64-MDCT) results. METHODS This study included a total of 22 patients (59.3 ± 16.6 ...

متن کامل

Bubbles in the left cardiac cavities after diving.

ventricular volumes and ejection fraction using 3-dimensional echocardiography with a full matrix-array transducer: comparison with magnetic resonance imaging. J Am Soc Echocardiogr 2005;18:779–88. 22. Sugeng L, Mor-Avi V, Weinert L, et al. Quantitative assessment of left ventricular size and function: side-by-side comparison of real-time three-dimensional echocardiography and computed tomograp...

متن کامل

Quantitative assessment of left ventricular size and function: side-by-side comparison of real-time three-dimensional echocardiography and computed tomography with magnetic resonance reference.

BACKGROUND Cardiac CT (CCT) and real-time 3D echocardiography (RT3DE) are being used increasingly in clinical cardiology. CCT offers superb spatial and contrast resolution, resulting in excellent endocardial definition. RT3DE has the advantages of low cost, portability, and live 3D imaging without offline reconstruction. We sought to compare both CCT and RT3DE measurements of left ventricular s...

متن کامل

Correlation of coronary artery stenosis evaluation with left heart structure and function by multi-slice computed tomography.

The aim of this study was to determine the impact of multi-slice computed tomography (MSCT) evaluation of coronary artery stenosis on left heart structure and systolic function. Coronary artery CT angiography was performed in 200 patients diagnosed with coronary heart disease, and then according to the AHA coronary artery 17-segment fractionation method, the Gensini score (GS) was determined fo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology

دوره 11 3  شماره 

صفحات  -

تاریخ انتشار 2010