Clinical evaluation of an inspiratory impedance threshold device during standard cardiopulmonary resuscitation in patients with out-of-hospital cardiac arrest.
نویسندگان
چکیده
OBJECTIVE To determine whether an impedance threshold device, designed to enhance circulation, would increase acute resuscitation rates for patients in cardiac arrest receiving conventional manual cardiopulmonary resuscitation. DESIGN Prospective, randomized, double-blind, intention-to-treat. SETTING Out-of-hospital trial conducted in the Milwaukee, WI, emergency medical services system. PATIENTS Adults in cardiac arrest of presumed cardiac etiology. INTERVENTIONS On arrival of advanced life support, patients were treated with standard cardiopulmonary resuscitation combined with either an active or a sham impedance threshold device. MEASUREMENTS AND MAIN RESULTS We measured safety and efficacy of the impedance threshold device; the primary end point was intensive care unit admission. Statistical analyses performed included the chi-square test and multivariate regression analysis. One hundred sixteen patients were treated with a sham impedance threshold device, and 114 patients were treated with an active impedance threshold device. Overall intensive care unit admission rates were 17% with the sham device vs. 25% in the active impedance threshold device (p = .13; odds ratio, 1.64; 95% confidence interval, 0.87, 3.10). Patients in the subgroup presenting with pulseless electrical activity had intensive care unit admission and 24-hr survival rates of 20% and 12% in sham (n = 25) vs. 52% and 30% in active impedance threshold device groups (n = 27) (p = .018, odds ratio, 4.31; 95% confidence interval, 1.28, 14.5, and p = .12, odds ratio, 3.09; 95% confidence interval, 0.74, 13.0, respectively). A post hoc analysis of patients with pulseless electrical activity at any time during the cardiac arrest revealed that intensive care unit and 24-hr survival rates were 20% and 11% in the sham (n = 56) vs. 41% and 27% in the active impedance threshold device groups (n = 49) (p = .018, odds ratio, 2.82; 95% confidence interval, 1.19, 6.67, and p = .037, odds ratio, 3.01; 95% confidence interval, 1.07, 8.96, respectively). There were no statistically significant differences in outcomes for patients presenting in ventricular fibrillation and asystole. Adverse event and complication rates were also similar. CONCLUSIONS During this first clinical trial of the impedance threshold device during standard cardiopulmonary resuscitation, use of the new device more than doubled short-term survival rates in patients presenting with pulseless electrical activity. A larger clinical trial is underway to determine the potential longer term benefits of the impedance threshold device in cardiac arrest.
منابع مشابه
Clinical Investigations Clinical evaluation of an inspiratory impedance threshold device during standard cardiopulmonary resuscitation in patients with out-of-hospital cardiac arrest*
An inspiratory impedance threshold device (ITD) has recently been demonstrated to enhance vital organ perfusion and neurologically intact survival rates in animals in cardiac arrest during standard cardiopulmonary resuscitation (CPR) (1– 4). The ITD is a small, 35-mL device that can attach to a variety of airway adjuncts, including a facemask and endotracheal tube (Fig. 1). By selectively imped...
متن کاملEvaluation of an impedance threshold device in patients receiving active compression-decompression cardiopulmonary resuscitation for out of hospital cardiac arrest.
AIMS The purpose of this multicentre clinical randomized controlled blinded prospective trial was to determine whether an inspiratory impedance threshold device (ITD), when used in combination with active compression-decompression (ACD) cardiopulmonary resuscitation (CPR), would improve survival rates in patients with out-of-hospital cardiac arrest. METHODS AND RESULTS Patients were randomize...
متن کاملUse of an inspiratory impedance threshold valve during cardiopulmonary resuscitation: a progress report.
Building upon studies on the mechanism of active compression-decompression (ACD) cardiopulmonary resuscitation, a new inspiratory impedance threshold valve has been developed to enhance the return of blood to the thorax during the decompression phase of CPR. Use of this device results in a greater negative intrathoracic pressure during chest wall decompression. This leads to improved vital orga...
متن کاملActive compression-decompression resuscitation and impedance threshold device for out-of-hospital cardiac arrest: a systematic review and metaanalysis of randomized controlled trials.
OBJECTIVE Active compression-decompression resuscitation and impedance threshold device are proposed to improve survival of patients of cardiac arrest by lowering intrathoracic pressure and increasing cardiac output. The results of clinical studies of active compression-decompression resuscitation or impedance threshold device were controversial. This metaanalysis pooled results of randomized c...
متن کاملEvaluation of a prototypic inspiratory impedance threshold valve designed to enhance the efficiency of cardiopulmonary resuscitation.
OBJECTIVE Assess a prototype inspiratory impedance threshold valve (ITV) designed to enhance vital organ circulation during standard and active compression/decompression cardiopulmonary resuscitation (CPR). BACKGROUND The ITV attaches to commonly used airway assist devices and decreases intrathoracic pressure during the decompression (chest recoil) phase of CPR by creating a vacuum within the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Critical care medicine
دوره 33 4 شماره
صفحات -
تاریخ انتشار 2005