Hyperpolarization of nitrogen-15 nuclei by cross polarization and dissolution dynamic nuclear polarization.
نویسندگان
چکیده
Dynamic Nuclear Polarization (DNP) is often achieved by the direct transfer of polarization from electrons to nuclei such as 13C, induced by microwave saturation of the wings of narrow EPR lines of radicals like trityl. In the indirect approach on the other hand, DNP is used to transfer the polarization from the electrons of radicals such as nitroxides that have broad EPR lines to nuclear spins I = 1H, followed by cross-polarization (CP) from I = 1H to S = 13C or other nuclei with low gyromagnetic ratios. This approach is particularly attractive for S = 15N, since direct DNP yields modest polarizations P(15N) < 4% with build-up times that can be as long as τDNP(15N) > 2 h. In this paper, we show that CP from 1H to 15N at 1.2 K can yield P(15N) = 25% with τCP-DNP(15N) = 10-15 min. After rapid dissolution and transfer to a solution-state NMR spectrometer, a polarization P(15N) = 20% was observed at 300 K. The longitudinal relaxation times in solution can be as long as T1(15N) > 800 s in favorable cases.
منابع مشابه
Sensitive magnetic control of ensemble nuclear spin hyperpolarization in diamond.
Dynamic nuclear polarization, which transfers the spin polarization of electrons to nuclei, is routinely applied to enhance the sensitivity of nuclear magnetic resonance. This method is particularly useful when spin hyperpolarization can be produced and controlled optically or electrically. Here we show complete polarization of nuclei located near optically polarized nitrogen-vacancy centres in...
متن کاملCross polarization from (1)H to quadrupolar (6)Li nuclei for dissolution DNP.
Cross polarization from protons to quadrupolar (6)Li nuclei is combined with dynamic nuclear polarization of protons at 1.2 K and 6.7 T using TEMPOL as a polarizing agent followed by rapid dissolution. Compared to direct (6)Li DNP without cross-polarization, a higher nuclear spin polarization P((6)Li) can be obtained in a shorter time. A double resonance (1)H-(6)Li probe was designed that is eq...
متن کاملRoom-temperature in situ nuclear spin hyperpolarization from optically pumped nitrogen vacancy centres in diamond
Low detection sensitivity stemming from the weak polarization of nuclear spins is a primary limitation of magnetic resonance spectroscopy and imaging. Methods have been developed to enhance nuclear spin polarization but they typically require high magnetic fields, cryogenic temperatures or sample transfer between magnets. Here we report bulk, room-temperature hyperpolarization of (13)C nuclear ...
متن کاملCross Polarization for Dissolution Dynamic Nuclear Polarization Experiments at Readily Accessible
Cross polarization can provide significant enhancements with respect to direct polarization of low-c nuclei such as C. Substantial gains in sample throughput (shorter polarization times) can be achieved by exploiting shorter buildup times sDNP( H) \ sDNP( C). To polarize protons rather than low-c nuclei, nitroxide radicals with broad ESR resonances such as TEMPO are more appropriate than Trityl...
متن کاملCross-polarization for dissolution dynamic nuclear polarization.
Dynamic nuclear polarization (DNP) in combination with subsequent dissolution of the sample allows the detection of low-γ nuclei in the solution state with a signal gain of up to tens of thousand times compared to experiments starting from Boltzmann conditions. The long polarization build-up times of typically more than one hour are a drawback of this technique. The combination of dissolution D...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Review of scientific instruments
دوره 88 1 شماره
صفحات -
تاریخ انتشار 2017