New Six-Layer Magnetically-Shielded Room for MEG

نویسندگان

  • D. Cohen
  • U. Schläpfer
  • S. Ahlfors
  • M. Hämäläinen
  • E. Halgren
چکیده

A high performance magnetically-shielded room (MSR) has been built by Imedco, to house a 4-D MEG system, containing both gradiometers and magnetometers (Vectorview). The MSR consists of three nested enclosures, each consisting of a high-permeability magnetic layer plus an aluminum layer, where special care was given to the junctions of the inner aluminum layer. Measurements of the passive shielding factor yield 1,630 (64dB), 3,600 (71dB), 240,000 (107dB) , and 78,000,000 (158dB) at frequencies of 0.01 Hz, 0.10 Hz, 1.0 Hz, and 10 Hz respectively. Thus, our room is among the very good MSRs. In addition, an active system is being developed, now yielding an extra SF of 6-10 at 0.10 Hz; this needs improvement to reduce new electric train disturbances. Also, we plan to reduce disturbances generated by the inner high-permeability layer when it is mechanically perturbed, for example by walking in the room.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Note: Magnetic noise from the inner wall of a magnetically shielded room.

We measured the thermal magnetic noise generated by the inner high-permeability wall of a magnetically shielded room. This room houses a magnetoencephalogram (MEG), which contains 102 "small" identical magnetometers. For the measurement, we created two large magnetometers by summing the outputs of 46 magnetometers equally on the helmet's left and right side, to look at the summed noise of the r...

متن کامل

Real-time Noise Reduction: 4D Neuroimaging 2500WH System

The 2500WH MEG system by 4D Neuroimaging has magnetometer detectors that rely on real-time noise reduction in addition to shielding of a magnetically shielded room. Theoretically, the set of reference magnetometers and gradiometers, distant from the recording array, are sufficient to remove environmental noise through first order spatial variation within the shielded room. However, in magnetica...

متن کامل

MSR upgrade for clinical MEG

To accommodate the new Argos 500 MEG instrument [1] a general upgrade of the existing 2+1layer magnetically shielded room at the neurological department was necessary. Due to the innovative technology and the ambitious goal more stringent requirements where set for shielding performances and shielding anisotropy. The upgrade process of the existing MSR was carried out in cooperation with Advanc...

متن کامل

Acta Medica 03 2015 4355.indd

Magnetoencephalography (MEG) is the recording of the magnetic field produced by the flowing of ions in the brain. This article reports our experience in the application of MEG in patients and healthy volunteers in the Greek population. We provide a brief description of our research work. The MEG data were recorded in a magnetically shielded room with a whole-head 122 channel or an one-channel b...

متن کامل

Method development for ultra-low-field magnetic resonance imaging and magnetoencephalography

Aalto University, P.O. Box 11000, FI-00076 Aalto www.aalto.fi Author Juhani Dabek Name of the doctoral dissertation Method development for ultra-low-field magnetic resonance imaging and magnetoencephalography Publisher School of Science Unit Department of Biomedical Engineering and Computational Science Series Aalto University publication series DOCTORAL DISSERTATIONS 42/2014 Field of research ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002