Development and validation of a fluorescent microsphere immunoassay for soluble CD30 testing.

نویسندگان

  • Igor Pavlov
  • Thomas B Martins
  • Julio C Delgado
چکیده

Testing for soluble CD30 (sCD30), an indicator of Th2 immune response, is a useful prognostic marker in solid organ transplantation, lymphoproliferative disorders, autoimmunity, and various parasitic diseases. In this study we report the development and validation of a fluorescent microsphere immunoassay for the detection of sCD30 in serum, plasma, and culture supernatants. The dynamic range of this assay is 1 to 400 ng/ml, and the rate of recovery of various concentrations of recombinant sCD30 ranges from 97 to 116% (average recovery, 105%). The test showed a high degree of precision in both intra-assay and interassay studies (coefficients of variation, as high as 7% and 8%, respectively), with a sensitivity of 1 ng/ml. The normal reference range calculated for a cohort of 151 healthy individuals was 1 to 29 ng/ml. The clinical usefulness of the sCD30 fluorescent microsphere immunoassay was demonstrated by showing that levels of sCD30 have a positive correlation with specimens containing high titers of anti-double-stranded DNA antibodies and high titers of immunoglobulin G against Leishmania species. Given the multiplexing potential of the sCD30 fluorescent microsphere immunoassay reported in this study, it is expected that testing of sCD30 concentrations along with those of other cytokines will become an important diagnostic tool for selected immunological and inflammatory diseases where Th2-type cytokine responses have been reported.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Heterophile antibody interference in a multiplexed fluorescent microsphere immunoassay for quantitation of cytokines in human serum.

While modern immunoassays provide sensitive and specific means for the quantitation of cytokines in biological fluids, heterophile antibodies are still a well-recognized cause of interference in the measurement of cytokines in these assays. We have developed a multiplexed fluorescent microsphere immunoassay for the simultaneous quantification of 10 cytokines in only 75 microl of serum. During t...

متن کامل

Serum copper is decreased in premature newborns and increased in newborns with hemolytic jaundice.

with the individual protein testing capacity of the WB. The assay can be tailored to the requirements of screening or confirmatory testing as well as to the needs of specific vaccine studies. Vaccine trials could benefit greatly from a PBA that differentiates protected from infected individuals. Because large-scale vaccine studies are likely to be conducted in settings where conditions may not ...

متن کامل

Development of a fluorescent-microsphere immunoassay for detection of antibodies specific to equine arteritis virus and comparison with the virus neutralization test.

The development and validation of a microsphere immunoassay (MIA) to detect equine antibodies to the major structural proteins of equine arteritis virus (EAV) are described. The assay development process was based on the cloning and expression of genes for full-length individual major structural proteins (GP5 amino acids 1 to 255 [GP5(1-255)], M(1-162), and N(1-110)), as well as partial sequenc...

متن کامل

Soluble CD30 in Normal Pregnancy Pre-Eclampsia and Recurrent Pregnancy Loss

Background: Normal pregnancy is thought to be dependent on Th2 deviation, while Recurrent Pregnancy Loss (RPL) and Pre-eclampsia (PE) appear to be biased toward the Th1 immune response. It is believed that the soluble form of CD30 (sCD30) is an index of Th2 immune response or modulator of Th1/Th2 responses. Objective: The aim of this study was determination of the sCD30 level in RPL and PE pati...

متن کامل

Flow microsphere immunoassay-based method of virus quantitation.

A sensitive assay for adenovirus quantitation in vitro was developed using the flow microsphere immunoassay (FMIA) approach. Polystyrene microspheres were covalently coated with purified anti-adenoviral antibodies and incubated with virus-containing samples. After incubation, the samples were stained with DNA-specific fluorescent dyes, and microsphere-associated fluorescence was quantitated wit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical and vaccine immunology : CVI

دوره 16 9  شماره 

صفحات  -

تاریخ انتشار 2009