A reliable method for measuring proximal tibia and distal femur bone mineral density using dual-energy X-ray absorptiometry.
نویسندگان
چکیده
PURPOSE To assess the intra- and inter-rater reliability of a standardized protocol for measuring proximal tibia and distal femur bone mineral density (BMD) using dual-energy X-ray absorptiometry (DXA). METHODS Ten able-bodied individuals (7 males) participated in this study. During one measurement session, the knee of each participant was scanned twice by rater 1 using DXA. Both scans were analyzed twice by rater 1 as well as once by a second rater. Intraclass correlation coefficients (ICCs), standard error of measurements (SEMs) and smallest detectable differences (SDDs) were calculated for the outcome measures proximal tibia and distal femur BMD. A decision study was performed to determine the effect of study protocol adjustments (i.e. increasing the number of scan repetitions, or scan analyses by the same rater) on SEM and SDD values. RESULTS High intra- and inter-rater ICCs (0.97-0.98) were found for both proximal tibia and distal femur BMD. Low SEMs (0.017-0.028 g/cm(2)) and SDDs (0.047-0.077 g/cm(2)) were found, with a slightly better result for proximal tibia BMD. Increasing the number of scan analyses by the same rater did not markedly reduce SEM and SDD values, while increasing the number of scan repetitions did. CONCLUSIONS Proximal tibia and distal femur BMD can be reliably assessed with this method.
منابع مشابه
Comparison of Singh index accuracy and dual energy X-ray absorptiometry bone mineral density measurement for evaluating osteoporosis
Background: The Singh index is an inexpensive simple method to evaluate bone density, commonly used to assess osteoporosis is based on the radiological appearance of the trabecular bone structure of the proximal femur on a plain antero-posterior (AP) radiograph. The purpose of this study was to compare between Singh index and bone mineral density measurement using dual energy X-ray abs...
متن کاملComparison of Bone Mineral Density Measured by Dual X-ray, Axial Dual-energy Photon X-ray Absorptiometry and Laser Absorptiometry of Calcaneus
The objective of this study was to validate the use of bone mineral measurements of the calcaneus bone by dual X-ray and laser (DXL) in a cross-sectional study carried out in an osteoporosis clinic. Measurements of bone mineral density (BMD) at proximal femur and spine were obtained by dual-energy photon X-ray absorptiometry (DEXA). Osteoporosis was defined by a DEXA T-score <-2.5 at the femora...
متن کاملAssessment of bone mineral density with dual energy X-ray absorptiometry in pre- and post-menopausal women
Background: Osteoporosis is a chronic disease that contributes substantially to decrease physical activity and decline in the quality of life. Osteoporosis can be diagnosed easily with the use of dual-energy X-ray absorptiometry (DXA) equipment. The aim of this study was to investigate the magnitude of bone loss on proximal femur and lumbar spine LS in pre- and post-menopausal women f...
متن کاملTexture analysis of X-ray radiographs is a more reliable descriptor of bone loss than mineral content in a rat model of localized disuse induced by the Clostridium botulinum toxin.
Botulism is a generalized paralyzing disease caused by the toxin of Clostridium botulinum (BTX). The toxin acts 3-4 days after injection by blocking the release of acetylcholine to the muscle. Six Wistar rats received a 2-U injection of BTX in the right quadriceps. Six rats were similarly injected with saline and were used as control. Paralysis of the quadriceps was obtained 4-5 days after the ...
متن کاملBone density study of the proximal femur after hip arthroplasty with porous-coated implants
Progressive loss of bone mineral density around the femora! component of total hip replacement continues to pose a threat to long term prosthetic survival. A linear study was undertaken to measure bone mineral density on a monthly basis following total hip arthroplasty in 11 male patients. The opposite femur was used as the control measurement. Bone mineral density was unchanged at two mo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical engineering & physics
دوره 36 3 شماره
صفحات -
تاریخ انتشار 2014