Drift and Cost Comparison of Different Structural Systems for Tall Buildings
نویسندگان
چکیده
The race towards new heights and architecture has not been without challenges. Tall structures have continued to climb higher and higher facing strange loading effects and very high loading values due to dominating lateral loads. The design criteria for tall buildings are strength, serviceability, stability and human comfort. But the factors govern the design of tall and slender buildings all the times are serviceability and human comfort against lateral loads. As a result, lateral stiffness is a major consideration in the design of tall buildings. The first parameter that is used to estimate the lateral stiffness of a tall building is drift index. Different lateral load resisting structural subsystems can be used to impart stiffness and reduce drift in the building. Lateral load resisting subsystems can take many forms depending upon the orientation, integration and addition of the various structural components. In this research, sixteen different lateral load resisting structural subsystems are used to design a tall building and finally the most economical structural system is selected amongst these. For this purpose a hundred and five storey square shaped prismatic steel building uniform through the height is selected, analyzed and designed for gravity and wind loads. Analysis and design of selected lateral load resisting structural subsystems reveals that, for the building configuration selected, the structural system containing composite super columns with portals subsystem is most efficient.
منابع مشابه
OPTIMUM LAYOUT OF NONLINEAR FLUID VISCOUS DAMPER FOR IMPROVEMENT THE RESPONSES OF TALL BUILDINGS
The utilization of passive energy dissipation systems has been created a revolution in the structural engineering industry due to their advantages. Fluid Viscous Damper (FVD) is one of these control systems. It has been used in many different industries, such as the army, aerospace, bridge, and building structures. One of the essential questions about this system is how it can combine with the ...
متن کاملParametric Study of Qutrigger Braced and Belt System in Tall Building Structures
Current innovative lateral load carrying systems for tall buildings are those in which the lateral drift is limited to an allowable value without considerable influence on economy. This aim is achieved by using special systems capable of using maximum stiffness and strength capacity of individual structural elements. An effective structural solution in this respect is the use of outrigger brace...
متن کاملParametric Study of Qutrigger Braced and Belt System in Tall Building Structures
Current innovative lateral load carrying systems for tall buildings are those in which the lateral drift is limited to an allowable value without considerable influence on economy. This aim is achieved by using special systems capable of using maximum stiffness and strength capacity of individual structural elements. An effective structural solution in this respect is the use of outrigger brace...
متن کاملRanking Passive Seismic Control Systems by Their Effectiveness in Reducing Responses of High-Rise Buildings with Concrete Shear Walls Using Multiple-Criteria Decision Making
In recent decades, the dual systems of steel moment-resisting frames and RC shear walls have found extensive application as lateral load-resisting systems for high-rise structures in seismically active areas. This paper investigated the effectiveness of tuned mass damper (TMD), viscous damper, friction damper, and the lead-core rubber bearing in controlling the damage and seismic response of hi...
متن کاملAnalyzing the Behavior of Hybrid Steel System of Tube in Tube with Bracing and Belt Truss
Nowadays, due to the escalation in construction of high-rise structures, the need for selecting a proper resistant structural system against earthquake and wind has increased significantly. These systems should show an optimized use of materials and should be presented as a hard and efficient structure. A good example of a high efficient system in high-rise buildings can be indicated is, the tu...