Patient-Specific 3D Reconstruction of a Complete Lower Extremity from 2D X-rays

نویسندگان

  • Guoyan Zheng
  • Steffen Schumann
  • Alper Alcoltekin
  • Branislav Jaramaz
  • Lutz-Peter Nolte
چکیده

In clinical routine surgeons depend largely on 2D x‐ray radiographs and their experience to plan and evaluate surgical interventions at the knee. Numerous studies have shown that pure 2D x‐ray radiography based measurements are not accurate due to the error in determining accurate radiography magnification and the projection characteristics of 2D radiographs. Using 2D x‐ray radiographs to plan 3D knee joint surgery may lead to component misalignment in KA or to over‐ or under‐correction of the mechanical axis of the lower extremity in LEO.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reconstruction of 3D Patient-Specific Bone Models From Biplanar X-Ray Images Utilizing Morphometric Measurements

Obtaining 3D patient-specific bone models from 2D image data (e.g. X-rays, fluoroscope) remains a practical and desirable alternative to segmentation of bone models from 3D image data (e.g. CT, MRI). It also provides an initial step to automatically calculating the relevant axes and angles needed in computer aided surgery (CAS). Our method utilizes a statistical atlas of bone based on Principal...

متن کامل

A Genetic Algorithm based Optimization Method in 3D Solid Reconstruction from 2D Multi-View Engineering Drawings

There are mainly two categories for a 3D reconstruction from 2D drawings: B-Rep and CSG that both these methods have serious weaknesses despite being useful. B-Rep method which has been older and have wider function range is problematic because of high volume of calculations and vagueness in answers and CSG method has problem in terms of very limited range of volumes and drawings that it can an...

متن کامل

Volume-of-change cone-beam CT for image-guided surgery.

C-arm cone-beam CT (CBCT) can provide intraoperative 3D imaging capability for surgical guidance, but workflow and radiation dose are the significant barriers to broad utilization. One main reason is that each 3D image acquisition requires a complete scan with a full radiation dose to present a completely new 3D image every time. In this paper, we propose to utilize patient-specific CT or CBCT ...

متن کامل

EOS(®) biplanar X-ray imaging: concept, developments, benefits, and limitations.

PURPOSE In 1992, Georges Charpak invented a new type of X-ray detector, which in turn led to the development of the EOS(®) 2D/3D imaging system. This system takes simultaneous anteroposterior and lateral 2D images of the whole body and can be utilized to perform 3D reconstruction based on statistical models. The purpose of this review is to present the state of the art for this EOS(®) imaging t...

متن کامل

Enhancement of mobile C-arm cone-beam reconstruction using prior anatomical models.

We demonstrate an improvement to cone-beam tomographic imaging by using a prior anatomical model. A protocol for scanning and reconstruction has been designed and implemented for a conventional mobile C-arm: a 9 inch image-intensifier OEC-9600. Due to the narrow field of view (FOV), the reconstructed image contains strong truncation artifacts. We propose to improve the reconstructed images by f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016