INTRODUCTION The Health Assessment Questionnaire Disability Index (HAQ) and the SF-36 PF-10, among other instruments, yield sensitive and valid Disability (Physical Function) endpoints. Modern techniques, such as Item Response Theory (IRT), now enable development of more precise instruments using improved items. The NIH Patient Reported Outcomes Measurement Information System (PROMIS) is charged with developing improved IRT-based tools. We compared the ability to detect change in physical function using original (Legacy) instruments with Item-Improved and PROMIS IRT-based instruments. METHODS We studied two Legacy (original) Physical Function/Disability instruments (HAQ, PF-10), their item-improved derivatives (Item-Improved HAQ and PF-10), and the IRT-based PROMIS Physical Function 10- (PROMIS PF 10) and 20-item (PROMIS PF 20) instruments. We compared sensitivity to detect 12-month changes in physical function in 451 rheumatoid arthritis (RA) patients and assessed relative responsiveness using P-values, effect sizes (ES), and sample size requirements. RESULTS The study sample was 81% female, 87% Caucasian, 65 years of age, had 14 years of education, and had moderate baseline disability. All instruments were sensitive to detecting change (< 0.05) in physical function over one year. The most responsive instruments in these patients were the Item-Improved HAQ and the PROMIS PF 20. IRT-improved instruments could detect a 1.2% difference with 80% power, while reference instruments could detect only a 2.3% difference (P < 0.01). The best IRT-based instruments required only one-quarter of the sample sizes of the Legacy (PF-10) comparator (95 versus 427). The HAQ outperformed the PF-10 in more impaired populations; the reverse was true in more normal populations. Considering especially the range of severity measured, the PROMIS PF 20 appears the most responsive instrument. CONCLUSIONS Physical Function scales using item improved or IRT-based items can result in greater responsiveness and precision across a broader range of physical function. This can reduce sample size requirements and thus study costs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Item response theory, computerized adaptive testing, and PROMIS: assessment of physical function.

OBJECTIVE Patient-reported outcome (PRO) questionnaires record health information directly from research participants because observers may not accurately represent the patient perspective. Patient-reported Outcomes Measurement Information System (PROMIS) is a US National Institutes of Health cooperative group charged with bringing PRO to a new level of precision and standardization across dise...

متن کامل

Using item response theory to enrich and expand the PROMIS® pediatric self report banks

BACKGROUND The primary objective was to enhance the content coverage of some of the pediatric self-report item banks for ages 8-17 years from the National Institutes of Health (NIH) Patient Reported Outcomes Measurement Information System (PROMIS®), and extend the range of precise measurement to higher levels of physical functioning. METHODS Data from 1,419 pediatric patients with cancer, chr...

متن کامل

Responsiveness and minimally important difference for the patient-reported outcomes measurement information system (PROMIS) 20-item physical functioning short form in a prospective observational study of rheumatoid arthritis.

OBJECTIVE To estimate responsiveness (sensitivity to change) and minimally important difference (MID) for the Patient-Reported Outcomes Measurement Information System (PROMIS) 20-item physical functioning scale (PROMIS PF-20). METHODS The PROMIS PF-20, short form 36 (SF-36) physical functioning scale, and Health Assessment Questionnaire (HAQ) were administered at baseline, and 6 and 12 months...

متن کامل

Better assessment of physical function: item improvement is neglected but essential

INTRODUCTION Physical function is a key component of patient-reported outcome (PRO) assessment in rheumatology. Modern psychometric methods, such as Item Response Theory (IRT) and Computerized Adaptive Testing, can materially improve measurement precision at the item level. We present the qualitative and quantitative item-evaluation process for developing the Patient Reported Outcomes Measureme...

متن کامل

Two-item PROMIS® global physical and mental health scales

Background: Self-reports of health provide useful information about function and well-being that can improve communication between patients and clinicians. Global health items provide summary information that are predictive of health care utilization and mortality. There is a need for parsimonious global health scales for use in large sample surveys. This study evaluates the reliability and val...