Radial Artery Applanation Tonometry for Continuous Noninvasive Cardiac Output Measurement: A Comparison With Intermittent Pulmonary Artery Thermodilution in Patients After Cardiothoracic Surgery.
نویسندگان
چکیده
OBJECTIVES Radial artery applanation tonometry allows completely noninvasive continuous cardiac output estimation. The aim of the present study was to compare cardiac output measurements obtained with applanation tonometry (AT-CO) using the T-Line system (Tensys Medical, San Diego, CA) with cardiac output measured by intermittent pulmonary artery thermodilution using a pulmonary artery catheter (PAC-CO) with regard to accuracy, precision of agreement, and trending ability. DESIGN A prospective method comparison study. SETTING The study was conducted in a cardiosurgical ICU of a German university hospital. PATIENTS We performed cardiac output measurements in 50 patients after cardiothoracic surgery. INTERVENTIONS None. MEASUREMENTS AND MAIN RESULTS Three independent sets of three consecutive thermodilution measurements (i.e., PAC-CO) each were performed per patient, and AT-CO was measured simultaneously. The average of the three thermodilution cardiac output measurements was compared with the average of the corresponding three AT-CO values resulting in 150 paired cardiac output measurements. In 13 patients, cardiac output-modifying maneuvers performed for clinical reasons additionally allowed to evaluate trending ability. For statistical analysis, we used Bland-Altman analysis, the percentage error, four-quadrant plot, and concordance analysis. Mean PAC-CO was 4.7 ± 1.2 L/min and mean AT-CO was 4.9 ± 1.1 L/min. The mean of differences was -0.2 L/min with 95% limits of agreement of -1.8 to + 1.4 L/min. The percentage error was 34%. The concordance rate was 95%. CONCLUSIONS Continuous cardiac output measurement using the noninvasive applanation tonometry technology is basically feasible in ICU patients after cardiothoracic surgery. The applanation tonometry technology provides cardiac output values with reasonable accuracy and precision of agreement compared with intermittent pulmonary artery thermodilution measurements in a clinical study setting and is able to reliably track cardiac output changes induced by cardiac output-modifying maneuvers.
منابع مشابه
Continuous and intermittent cardiac output measurement: pulmonary artery catheter versus aortic transpulmonary technique.
BACKGROUND Cardiac output (CO) can be measured intermittently by bolus thermodilution methods in the pulmonary artery (COpa) or in the aorta (COart). A continuous thermodilution method (CCO) and a method for continuous estimation using the arterial pulse wave (PCCO) are also available. METHODS We compared two methods of intermittent CO measurements in patients during liver transplantation: CO...
متن کاملComparison of esophageal Doppler, pulse contour analysis, and real-time pulmonary artery thermodilution for the continuous measurement of cardiac output.
OBJECTIVE Continuous measurement of cardiac output (CCO) is of great importance in the critically ill. However, pulmonary artery thermodilution has been questioned for possible complications associated with right heart catheterization. Furthermore, measurements are delayed in the continuous mode during rapid hemodynamic changes. A new pulmonary artery catheter CCO device (Aortech, Bellshill, Sc...
متن کاملPleth variability index and fluid responsiveness of hemodynamically stable patients after cardiothoracic surgery.
BACKGROUND Fluid responsiveness is a measure of preload dependence and is defined as an increase in cardiac output due to volume expansion. Recent publications have suggested that variation in amplitude of the pulse oximetry waveform may be predictive of fluid responsiveness. The pleth variability index (PVI) was developed as a noninvasive bedside measurement of this variation in the pulse oxim...
متن کاملComparison of Cardiac Output Measurement by Noninvasive Methodwith Electrical Cardiometry and Invasive Method with Thermodilution Technique in Patients Undergoing Coronary Artery Bypass Grafting
Objective: This study was conducted to compare the cardiac output by using Electrical Cardiometry (EC), a noninvasive method of continuous cardiac output monitoring during cardiac surgery with pulmonary artery catheter (PAC) derived cardiac output. Design: Prospective observational clinical study. Setting: Cardiac surgery operating room of a tertiary care cardiac center. Participants: Twenty fi...
متن کاملNoninvasive continuous cardiac output monitoring in perioperative and intensive care medicine.
The determination of blood flow, i.e. cardiac output, is an integral part of haemodynamic monitoring. This is a review on noninvasive continuous cardiac output monitoring in perioperative and intensive care medicine. We present the underlying principles and validation data of the following technologies: thoracic electrical bioimpedance, thoracic bioreactance, vascular unloading technique, pulse...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Critical care medicine
دوره 43 7 شماره
صفحات -
تاریخ انتشار 2015