Accuracy of StepWatch™ and ActiGraph Accelerometers for Measuring Steps Taken among Persons with Multiple Sclerosis
نویسندگان
چکیده
INTRODUCTION There has been increased interest in the objective monitoring of free-living walking behavior using accelerometers in clinical research involving persons with multiple sclerosis (MS). The current investigation examined and compared the accuracy of the StepWatch activity monitor and ActiGraph model GT3X+ accelerometer for capturing steps taken during various speeds of prolonged, over-ground ambulation in persons with MS who had mild, moderate, and severe disability. METHODS Sixty-three persons with MS underwent a neurological examination for generation of an EDSS score and undertook two trials of walking on the GAITRite electronic walkway. Participants were fitted with accelerometers, and undertook three modified six-minute walk (6MW) tests that were interspersed with 10-15 minutes of rest. The first 6MW was undertaken at a comfortable walking speed (CWS), and the two remaining 6MW tests were undertaken above (faster walking speed; FWS) or below (slower walking speed; SWS) the participant's CWS. The actual number of steps taken was counted through direct observation using hand-tally counters. RESULTS The StepWatch activity monitor (99.8%-99.9%) and ActiGraph model GT3X+ accelerometer (95.6%-97.4%) both demonstrated highly accurate measurement of steps taken under CWS and FWS conditions. The StepWatch had better accuracy (99.0%) than the ActiGraph (95.5%) in the overall sample under the SWS condition, and this was particularly apparent in those with severe disability (StepWatch: 95.7%; ActiGraph: 87.3%). The inaccuracy in measurement for the ActiGraph was associated with alterations of gait (e.g., slower gait velocity, shorter step length, wider base of support). CONCLUSIONS This research will help inform the choice of accelerometer to be adopted in clinical trials of MS wherein the monitoring of free-living walking behavior is of particular value.
منابع مشابه
Validity of the Fitbit activity tracker for measuring steps in community-dwelling older adults
BACKGROUND Commercially available activity monitors, such as the Fitbit, may encourage physical activity. However, the accuracy of the Fitbit in older adults remains unknown. This study aimed to determine (1) the criterion validity of Fitbit step counts compared to visual count and ActiGraph accelerometer step counts and (2) the accuracy of ActiGraph step counts compared to visual count in comm...
متن کاملDoes a waist-worn ActiGraph accelerometer quantify community ambulation in persons with multiple sclerosis?
Accelerometry has been recognized as a method of objectively measuring community ambulation in persons with multiple sclerosis (MS). However, the assumption that walking itself serves as a major contributor to the accelerometer signal has yet to be tested. This study examined the assumption that community-based walking is a primary contributor to accelerometer output in MS. Ambulatory persons (...
متن کاملClinical Importance of Steps Taken per Day among Persons with Multiple Sclerosis
BACKGROUND The number of steps taken per day (steps/day) provides a reliable and valid outcome of free-living walking behavior in persons with multiple sclerosis (MS). OBJECTIVE This study examined the clinical meaningfulness of steps/day using the minimal clinically important difference (MCID) value across stages representing the developing impact of MS. METHODS This study was a secondary ...
متن کاملFalls and Physical Activity in Persons with Multiple Sclerosis
Objectives. To examine the association between fall history and physical activity using an objective measure of physical activity (i.e., accelerometry) in persons with multiple sclerosis. Design. A community-based sample of 75 ambulatory persons with multiple sclerosis volunteered for the investigation. Participants self-reported fall history in the last year, underwent a neurological exam to d...
متن کاملMobility disability and the pattern of accelerometer-derived sedentary and physical activity behaviors in people with multiple sclerosis.
OBJECTIVE Low physical activity and high sedentary behavior levels are major concerns in persons with multiple sclerosis (MS) and these differ depending on the level of mobility disability. However, the manner in which daily activity is accumulated is currently unknown in this population. METHODS A secondary analysis was performed on a combined data set of persons with MS from two previous in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 9 شماره
صفحات -
تاریخ انتشار 2014