An Interference-Filter Monochromator System for the Irradiation of Biological Material.

نویسنده

  • R B Withrow
چکیده

The determination of action spectra for biological photoreactions requires that large areas be irradiated uniformly at high intensities and with narrow band widths for the resolution of spectral details: When the material is changing irreversibly with time or when long irradiation periods are required, it may be necessary to irradiate samples at ten or more different points in the spectrum simultaneously. This excludes use of the conventional single-exit-slit monochromator and requires a spectrograph with a series of wide slits arranged in the focal plane of the spectrum. The necessity of both high radiant power and narrow band width are difficult to meet with the prism or grating spectrograph. These instruments are capable of producing band widths of a small fraction of a millimicron but the intensity of the beam falls rapidly as the waveband is decreased. Large prism (8) and grating (7) spectrograph systems using 5 to 15 kw carbon-arc sources have been described for the simultaneous irradiation of relatively large objects with monochromatic energy at many wayelengths. The band width of such systems is usually from 5 to 20 m,u when the radiant power is sufficiently high. The properties and application of these systems have been discussed elsewhere (14). The principal practical limitations of the spectrograph system are: 1) the large space required, 2) the unequal irradiance distribution over the spectrum, and 3) the cross-scattering of energy between wavelength stations. Because of the magnification required of the optical system, it is necessary to project the beam over relatively large distances of 5 to 15 meters. The relative intensity distribution between the various wavelength stations is arbitrarily determined by the spectral energy distribution of the source and transmission of the spectrograph. Therefore, it is not possible to obtain an equal irradiance or equal quantum-intensity spectrum. While this is not always essential for action spectrum studies, it is certainly desirable for convenience of analysis and interpretation of results. It is especially desirable for biological svstems for which reciprocity does not hold. The interference-filter monochromator presents several important advantages over the prism and grating instruments. A system of 10 or 20 wavelength stations can be placed in a relatively small constantcondition room. The spectral bands can be completely isolated in small cabinets and the intensity of each wavelength station adjusted independently by electrical control of the source or by neutral density filters so as to produce an equal irradiance or equal

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Novel Active Filter for Mitigation of EMI and Other Adverse Effects of PWM Inverter-Fed AC Motor

This paper presents novel active filter for mitigation electromagnetic interference (EMI) and other adverse effects of pulse width modulation (PWM) inverter-fed AC motor system. An active filter proposed and devised for this system is characterized by sophisticated connection of two small separate filters, capable of mitigating all the adverse effects. This paper provides high frequency models ...

متن کامل

Delay Spoofing Reduction in GPS Navigation System based on Time and Transform Domain Adaptive Filtering

Due to widespread use of Global Positioning System (GPS) in different applications, the issue of GPS signal interference cancelation is becoming an increasing concern. One of the most important intentional interferences is spoofing signals. An effective interference (delay spoof) reduction method based on adaptive filtering is developed in this paper. The principle of method is using adaptive f...

متن کامل

A Novel Interference Rejection Method for GPS Receivers

This paper proposes a new method for rejecting the Continuous Wave Interferences (CWI) in the Global Positioning System (GPS) receivers. The proposed filter is made by cascading an adaptive Finite Impulse Response (FIR) filter and a Wavelet Packet Transform (WPT) based filter. Although adaptive FIR filters are easy to implement and have a linear phase, they create self-noise in the rejection of...

متن کامل

Interference Mitigation of Replay Attacks in GPS Receiver using of Finite Impulse Response Filter

The vulnerability of civil GPS receiver to interference may be intentional or unintentional. Among all types of interference, replay attack intended as the most dangerous intentional one. The signal structure of replay attack is almost the same with the satellite signal. The interference effects can be reduce with the design of an appropriate filter in the receiver. This paper presents two meth...

متن کامل

A useful monochromator drive system for spectral scanning.

HALLDAL[l] describes the use of an interference-wedge filter as a simple monochromator for recording different types of spectra. His use of the cam and screen to obtain equal quanta is particularly clever. We have used interference-wedge filters in a similar way for the purpose of recording fluorescence emission spectra[2,3]. I t is frequently useful and efficient to be able to change the scann...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Plant physiology

دوره 32 4  شماره 

صفحات  -

تاریخ انتشار 1957