Primary polypseudophakia for cataract surgery in hypermetropic eyes: refractive results and long term stability of the implants within the capsular bag.
نویسندگان
چکیده
AIM To determine the long term visual and refractive results, and stability and complications of primary polypseudophakia using poly(methylmethacrylate) (PMMA) intraocular lenses (IOLs) for cataract surgery in hypermetropic eyes. METHODS Prospective study of 15 short or hypermetropic eyes undergoing phacoemulsification with primary polypseudophakia with two PMMA IOLs implanted within the capsular bag. RESULTS The spherical equivalent was reduced from a mean +4.87 (SD 3.00) dioptres (D) to -0.12 (1.40 D), and the deviation from the intended refraction was +0.005 (1.30) D, 23.6 (12.36) months post-implantation. The deviation from intended refraction was not statistically significant (p = 0.989; paired t test). Postoperative best corrected visual acuity (BCVA) was 6/12 or better in all eyes without macular or optic nerve co-morbidity. Interlenticular opacification (ILO) in the form of peripheral Elschnig pearls was seen in four (26.67%) eyes. A new type of ILO in the form of usually pigmented deposits in the central interface developed in five (33.33%) eyes and resulted in the appearance of Newton's rings in three. None of the eyes with ILO had any loss of BCVA or hyperopic shift. Six (40%) eyes were within 1 D from the intended refraction and 14 (93.33%) within 2 D. There was no statistically significant difference in the accuracy of the two intraocular lens calculation formulas used (SRK II and SRK/T). CONCLUSION Peripheral Elschnig pearl-type ILO can occur as a late complication of primary in the bag implantation of two PMMA IOLs. A new type of ILO is described. Both types of ILO have not to date resulted in deterioration of visual acuity in our cohort. Use of appropriate biometry techniques and IOL calculation formulas may yield more accurate refractive results.
منابع مشابه
Investigation of visual acuity and residual refractive error after cataract surgery in patients with senile cataract by phacoemulsification
Background and Aim: Vision improvement and reduction of refractive errors are considered as important goals of cataract surgery. The purpose of this study was to evaluate residual refractive errors after cataract surgery in the patients with senile cataract in Shahid Rahimi Hospital in Khorramabad City between 2017 and 2018. Material and Methods: This cross-sectional study included 178 patients...
متن کاملTemporary Piggyback Intraocular Lens Implantation Versus Single Intraocular Lens Implantation in Congenital Cataracts: Long-Term Clinical Outcomes.
Purpose To report the long-term results of temporary piggyback IOL implantation in congenital cataract and to compare the clinical outcomes of temporary piggyback IOL with those of single IOL implantation. Methods This is a retrospective, comparative, interventional study. The medical records of all consecutive patients who underwent cataract extraction and single or temporary piggyback IOL i...
متن کاملRefractive Error and Anterior Segment Parametric Changes in Patients with Posterior Capsular Opacification after Nd: YAG Laser Posterior Capsulotomy
Background and Objective: Cataract is one of the most common causes of blindness in the world, and posterior capsular opacification (PCO) is the most common complication after cataract surgery. Nd: YAG laser posterior capsulotomy is a standard method for the treatment of PCO. The aim of this study was to investigate the effects of Yas laser capsulotomy on anterior segment parameters and lenticu...
متن کاملLong-term outcomes of ciliary sulcus versus capsular bag fixation of intraocular lenses in children: An ultrasound biomicroscopy study
PURPOSE To evaluate the long-term outcomes of ciliary sulcus versus capsular bag fixation of intraocular lenses (IOLs) in children after pediatric cataract surgery. METHODS IOL was implanted in the ciliary sulcus in 21 eyes of 14 children, and in the capsular bag in 19 eyes of 12 children for the treatment of pediatric cataract in an institutional setting. Ultrasound biomicroscopy (UBM) was p...
متن کاملHydrophilic Acrylic versus PMMA Intraocular Lens Implantation in Pediatric Cataract Surgery
PURPOSE To compare primary implantation of foldable hydrophilic acrylic with polymethylmethacrylate (PMMA) intraocular lenses (IOLs) in pediatric cataract surgery in terms of short-term complications and visual outcomes. METHODS This randomized clinical trial included 40 eyes of 31 consecutive pediatric patients aged 1 to 6 years with unilateral or bilateral congenital cataracts undergoing ca...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 85 10 شماره
صفحات -
تاریخ انتشار 2001