Influence of prosthesis type on long-term survival after re-replacement of aortic valve prosthesis.
نویسندگان
چکیده
BACKGROUND The purpose of this study is to examine the influence of the prosthesis type on early mortality and long-term survival after re-replacement of aortic valve prosthesis, especially in patients over 60 years old. METHODS Late outcome of 223 patients who underwent a reoperation on the aortic valve and received a mechanical (mechanical group) or biological (biological group) heart valve prosthesis at a single institution were analyzed for survival and major valve-related complications, including structural valve deterioration, thromboembolism, hemorrhage, further reoperation, and valve-related mortality. RESULTS Preoperative New York Heart Association class IV (P = 0.001), emergency procedure (P = 0.002), and endocarditis (P = 0.025) were significant risk factors for 30-day mortality rates, which were 8.4 % and 12.5 %, respectively (mechanical versus biological group, P = 0.361). A subanalysis of elective patients revealed a low risk of 30-day mortality of 2.4 % and 1.8 %, respectively. Event-free survival was comparable at 5 years (73.9% ± 3.6% versus 70.5% ± 6.5%, mechanical versus biological group) and 10 year (49.7% ± 5.0% versus 35.3% ± 9.8%, mechanical versus biological group). In a propensity-matched subanalysis, survival and event-free survival were comparable at 5 and 10 years in both groups. CONCLUSION The type of aortic valve prosthesis did not affect early outcome and late survival in patients who underwent valve replacement, and therefore, the current strategy favoring a biological aortic valve prosthesis for patients aged over 60 years in first-time operations could also be applied in re-replacement.
منابع مشابه
Aortic Valve replacement with Reduction Aortoplasty with Mesh Prosthesis in 75 years old with Sever aortic Regurgitation with Aortic Aneurysm
Although classic and standard procedure for patients with ascending Aorta aneurysm with Sever aortic Regurgitation is Bentall surgery but in some selected cases this complex surgery was not performed with different reason like advanced age and coexisting comorbidity involving renal and hepatic and lung Function. In our cases 75 years old man with chronic renal failure ( Cr= 3.2 ) who was known ...
متن کاملعوامل موثر بر علل جراحی مجدد دریچه های مصنوعی قلب و بقاء زودرس بعد عمل، بیمارستان امام، 80-1370
Prosthetic valve re-operation has greater mortality and morbidity than primary valve replacement. By recognition of factors influencing on causes of redo operation and preoperative survival, one can select appropriate prosthesis at primary valve replacement and when operation performed at appropriate time, surgical risk can be reduced.Methods and Materials: Two hundred patients that underwent p...
متن کاملProsthesis size and long-term survival after aortic valve replacement.
OBJECTIVE This study was undertaken to quantify the relationship between prosthesis size adjusted for patient size (prosthesis-patient size) and long-term survival after aortic valve replacement. METHODS Data from nine representative sources on 13,258 aortic valve replacements provided 69,780 patient-years of follow-up (mean 5.3 +/- 4.7 years), with reliable survival estimates to 15 years. Pr...
متن کامل[Influence of patient-prosthesis mismatch in the octogenarian undergoing surgery for aortic valve replacement due to severe stenosis].
INTRODUCTION AND OBJECTIVES The clinical impact of patient-prosthesis mismatch on the outcome in octogenarians who undergo surgery for aortic valve replacement due to severe stenosis is unknown. Our objective was to quantify the frequency of some degree of patient-prosthesis mismatch and its impact on mortality and life quality. METHODS We analyzed all the octogenarian patients who underwent ...
متن کاملRoot graft substitution after aortic valve replacement: sparing the valve prosthesis is a valid option.
OBJECTIVES Few case studies have shown the feasibility of the prosthesis-sparing operation in patients requiring aortic root replacement after aortic valve replacement. Such technique allows the sparing of a well-functioning aortic valve prosthesis and facilitates the root substitution with only a vascular graft. The aim of the present study was to assess short- and mid-term outcomes of the pat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The heart surgery forum
دوره 16 6 شماره
صفحات -
تاریخ انتشار 2013