Gonad shielding in paediatric pelvic radiography: disadvantages prevail over benefit

نویسندگان

  • Marij J. Frantzen
  • Simon Robben
  • Alida A. Postma
  • Johannes Zoetelief
  • Joachim E. Wildberger
  • Gerrit J. Kemerink
چکیده

OBJECTIVE To re-evaluate gonad shielding in paediatric pelvic radiography in terms of attainable radiation risk reduction and associated loss of diagnostic information. METHODS A study on patient dose and the quality of gonad shielding was performed retrospectively using 500 pelvic radiographs of children from 0 to 15 years old. In a subsequent study, 195 radiographs without gonad shielding were included. Patient doses and detriment adjusted risks for heritable disease and cancer were calculated with and without gonad shielding. RESULTS For girls, gonad shields were placed incorrectly in 91% of the radiographs; for boys, in 66%. Without gonad shielding, the hereditary detriment adjusted risk for girls ranged between 0.1 × 10(-6) and 1.3 × 10(-6) and for boys between 0.3 × 10(-6) and 3.9 × 10(-6), dependent on age. With shielding, the reduction in hereditary risk for girls was on average 6 ± 3% of the total risk of the radiograph, for boys 24 ± 6%. Without gonad shielding, the effective dose ranged from 0.008 to 0.098 mSv. CONCLUSIONS With modern optimised X-ray systems, the reduction of the detriment adjusted risk by gonad shielding is negligibly small. Given the potential consequences of loss of diagnostic information, of retakes, and of shielding of automatic exposure-control chambers, gonad shielding might better be discontinued.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gonad Shielding during Pelvic Radiography: A Systematic Review and Meta-analysis.

BACKGROUND Gonad shielding has been extensively advocated during pelvic radiography at or below reproductive ages. The popular practice of gonad shielding is placement of a lead shield in the midline of the pelvis. The aim of this study was to address the prevalence of gonad shielding and find out whether the current practice of gonad shielding can be considered as an effective method to reduce...

متن کامل

Radioprotection to the Gonads in Pediatric Pelvic Radiography: Effectiveness of Developed Bismuth Shield

Background: The use and effectiveness of traditional lead gonad shields in pediatric pelvic radiography has been challenged by several literatures over the past two decades. The aim of this study was to develop a new radioprotective gonad shields to be use in pediatric pelvic radiography. Materials and Methods: The commercially available 0.06 mm lead equivalent bismuth garment has cropped squar...

متن کامل

Evaluation of the Prevalence and Utility of Gonad Shielding in Pediatrics Undergoing Pelvic X-Ray

Background: Gonad shielding has been recommended during pelvic x-rays since the 1950s. The popular method of gonad shielding is placement a lead shield in the midline of the pelvis. The aim of this study was to evaluate the prevalence and utility of gonad shielding in pediatrics undergoing pelvic x-rays.Materials and MethodsFollowing study approval, we retrospectively retrieved data from the di...

متن کامل

Ovarian Shielding during Pelvis Radiography: Risk Versus Benefit

Radiography of the pelvis is one of the most common and more frequent radiographic examinations ordered, especially in children [1]. It is estimated that annually a million pelvic radiographs were documented in the UK [2] with frequency of 39 per 1000 of population [3]. Since the 1950s, much focus has been placed on pelvis x-ray examination due to it is associated with direct gonad irradiation ...

متن کامل

Gonad Protection During Paediatric Abdomen and Pelvic X-Ray Examinations

Background: Evidence suggests that children are more susceptible to radiation risks or hazards. In particular, their gonads are more sensitive to the effects of radiation, especially at or below reproductive age. Protecting the gonads of children and adults is of particular importance to the imaging. Aim: To investigate level of the use of gonad protection during paediatric abdomen and pelvic X...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -