Dosimetry for Beta-Emitter Radionuclides by Means of Monte Carlo Simulations

نویسندگان

  • Pedro Pérez
  • Francesca Botta
  • Guido Pedroli
  • Mauro Valente
چکیده

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cellular S-value of beta emitter radionuclide’s determined using Geant4 Monte Carlo toolbox, comparison to MIRD S-values

Introduction: Spatial dose distribution around the radionuclides sources is required for optimized treatment planning in radioimmunotherapy. At present, the main source of data for cellular dosimetry is the s-values provided by MIRD. However, the MIRD s-values have been calculated based on analytical formula in which no electrons straggling is taken to account. In this study, we used Geant4-DNA...

متن کامل

Cellular dosimetry of beta emitting radionuclides-antibody conjugates for radioimmunotherapy

Introduction: The choice of optimal radionuclides for radioimmunotherapy depends on several factors, especially the radionuclide and antibody. The dosimetric characteristics of a non-internalizing and an internalizing monoclonal antibody (MAb) labeled with beta emitting radionuclides were investigated. Methods: Using Geant4-DNA Monte Carlo simulation, we ...

متن کامل

Absorbed Dose Assessment from Short-Lived Radionuclides of Radon (222Rn) Decay Chain in Lung Tissue: A Monte Carlo Study

Introduction: Internal exposure to radon gas progeny can lead to serious biologic damages to the lung tissue. The aim of this study was to evaluate the absorbed dose by lung tissue due to the exposure from short-lived radioactive products of radon (222Rn) decay using Monte Carlo simulation. Material and Methods: A lung equivalent p...

متن کامل

Dosimetric analysis for the selection of radionuclides in bone pain palliation targeted therapy: A Monte Carlo simulation

Introduction:The use of beta emitters is one of the effective methods for palliation of bone metastasis. The risk of normal tissue toxicity should be evaluated in the bone pain palliation treatment. Methods: In this study, the Monte Carlo simulation code MCNPX was used for simulation a bone phantom model consisted of bone marrow, bone and soft tissue. Spe...

متن کامل

Evaluating the doismetric characteristics of some beta- emitter radionuclides for skin lesions irradiation

Introduction: The dosimetric characteristics of patch sources including 32P, 90Y, 188Re and 166Ho, which are employed for radionuclide skin therapy, have been evaluated in current study Materials and Methods: The patch sources understudy were modeled by MCNPX Monte Carlo code and corresponding depth dose distribution, transverse dose profile and isodose curves...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -