Evaluation of scatter correction methods using Monte Carlo simulation in non uniform media
نویسندگان
چکیده
The detection of scattered photons affects both image quality and accuracy of quantitation accuracy in Single Photon Emission Computed Tomography (SPECT). The aim of this work was to evaluate three scatter correction methods: Jaszczak subtraction, the triple energy window method and an artificial neural network based approach. This evaluation was performed not only in terms of contrast and spatial resolution but also in terms of absolute and relative quantitation. A Monte Carlo simulation of an anthropomorphic cardiac phantom allowed us to obtain a realistic SPECT study while knowing the primary (non scattered) photon distribution. The knowledge of the primary activity made possible the study of the effect of scatter alone independently on all other phenomena affecting quantitation. The quantitative error propagation between the projections and the reconstructed slices due to scatter was studied as well as resolution, contrast and uniformity recoveries in the corrected images. The results show that an artificial neural network achieved the best scatter correction both in terms of relative (gives the same uniformity as in the primary distribution) and absolute quantitation (error < 4%) and resolution. The triple energy window method led to good quantitation (error < 8%) and contrast results but poorer resolution recovery than the artificial neural network based approach. Jaszczak subtraction yielded good quantitation (error < 7%) but introduced severe non uniformities in the image (decrease of the uniformity by 35%).
منابع مشابه
A new approach to scatter correction in SPECT images based on Klein_Nishina equation
Introduction: Scattered photon is one of the main defects that degrade the quality and quantitative accuracy of nuclear medicine images. Accurate estimation of scatter in projection data of SPECT is computationally extremely demanding for activity distribution in uniform and non-uniform dense media. Methods: The objective of this paper is to develop and validate a scatter correction technique ...
متن کاملMonte Carlo Study of the Effect of Backscatter Materail Thickness on 99mTc Source Response in Single Photon Emission Computed Tomography
Introduction SPECT projections are contaminated by scatter radiation, resulting in reduced image contrast and quantitative errors. Backscatter constitutes a major part of the scatter contamination in lower energy windows. The current study is an evaluation of the effect of backscatter material on FWHM and image quality investigated by Monte Carlo simulation. Materials and Methods SIMIND program...
متن کاملDetermination of the Energy Windows for the Triple Energy Window Scatter Correction Method in Gadolinium-159 Single Photon Emission Computed Tomography Using Monte Carlo Simulation
Introduction: In radionuclide imaging, object scatter is one of the major factors leading to image quality degradation. Therefore, the correction of scattered photons might have a great impact on improving the image quality. Regarding this, the present study aimed to determine the main and sub-energy windows for triple energy window (TEW) scatter correction method usin...
متن کاملAttenuation Correction in SPECT during Image Reconstruction using an Inverse Monte Carlo Method: A Simulation Study
Introduction: The main goal of SPECT imaging is to determine activity distribution inside the organs of the body. However, due to photon attenuation, it is almost impossible to do a quantitative study. In this paper, we suggest a mathematical relationship between activity distribution and its corresponding projections using a transfer matrix. Monte Carlo simulation was used to find a precise tr...
متن کاملPlanar and SPECT Monte Carlo acceleration using a variance reduction technique in I131 imaging
Background: Various variance reduction techniques such as forced detection (FD) have been implemented in Monte Carlo (MC) simulation of nuclear medicine in an effort to decrease the simulation time while keeping accuracy. However most of these techniques still result in very long MC simulation times for being implemented into routine use. Materials and Methods: Convolution-based force...
متن کامل