Quantitative comparison of proteomic data quality between a 2D and 3D quadrupole ion trap.

نویسندگان

  • Adele R Blackler
  • Aaron A Klammer
  • Michael J MacCoss
  • Christine C Wu
چکیده

A 2D ion trap has a greater ion trapping efficiency, greater ion capacity before observing space-charging effects, and a faster ion ejection rate than a traditional 3D ion trap mass spectrometer. These hardware improvements should result in a significant increase in protein identifications from complex mixtures analyzed using shotgun proteomics. In this study, we compare the quality and quantity of peptide identifications using data-dependent acquisition of tandem mass spectra of peptides between two commercially available ion trap mass spectrometers (an LTQ and an LCQ XP Max). We demonstrate that the increased trapping efficiency, increased ion capacity, and faster ion ejection rate of the LTQ results in greater than 5-fold more protein identifications, better identification of low-abundance proteins, and higher confidence protein identifications when compared with a LCQ XP Max.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Systematic comparison of a two-dimensional ion trap and a three-dimensional ion trap mass spectrometer in proteomics.

The utility and advantages of the recently introduced two-dimensional quadrupole ion trap mass spectrometer in proteomics over the traditional three-dimensional ion trap mass spectrometer have not been systematically characterized. Here we rigorously compared the performance of these two platforms by using over 100,000 tandem mass spectra acquired with identical complex peptide mixtures and acq...

متن کامل

An interface with a linear quadrupole ion guide for an electrospray-ion trap mass spectrometer system.

A new ion sampling interface for an electrospray ionization 3D ion trap mass spectrometer system is described. The interface uses linear rf quadrupoles as ion guides and ion traps to enhance the performance of the 3D trap. Trapping ions in the linear quadrupoles is demonstrated to improve the duty cycle of the system. Dipolar excitation of ions trapped in a linear quadrupole is used to eject un...

متن کامل

Pulsed multiple reaction monitoring approach to enhancing sensitivity of a tandem quadrupole mass spectrometer.

Liquid chromatography (LC)-triple quadrupole mass spectrometers operating in a multiple reaction monitoring (MRM) mode are increasingly used for quantitative analysis of low-abundance analytes in highly complex biochemical matrixes. After development and selection of optimum MRM transitions, sensitivity and data quality limitations are largely related to mass spectral peak interferences from sa...

متن کامل

Evaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT

Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...

متن کامل

A comparison of 2D and 3D kidney absorbed dose measures in patients receiving 177Lu-DOTATATE

Objective(s): To investigate and compare quantitative accuracy of kidney absorbed dose measures made from both 2D and 3D imaging in patients receiving 177LuDOTATATE (Lutate) for treatment of neuroendocrine tumours (NETs). Methods: Patients receiving Lutate therapy underwent both whole body planar imaging and SPECT/CT imaging over the kidneys at time points 0.5, 4, 24, and 96-120 hours after inj...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 78 4  شماره 

صفحات  -

تاریخ انتشار 2006