MRI is unable to illustrate the absorption time of the absorbable TIGR mesh in humans: a case report

نویسندگان

  • Stina Öberg
  • Kristoffer Andresen
  • Jakob M. Møller
  • Jacob Rosenberg
چکیده

A male patient had a bilateral laparoscopic inguinal hernia repair in 2012. The right-sided hernia was treated with a permanent mesh, and the left-sided hernia received an absorbable mesh. The absorbable TIGR mesh has been proved to be completely absorbed and replaced by new connective tissue after 3 years in sheep. The patient was therefore followed for 3 years by annual magnetic resonance imagings (MRIs) to illustrate the absorption time in humans. During follow-up, the thickness of the absorbable mesh slightly decreased, and at the last clinical examination, the patient was without a recurrence. However, MRI failed to illustrate absorption of the TIGR mesh, perhaps since new connective tissue and the mesh material had the same appearance on the images. In conclusion, MRI was unable to confirm an absorption time of 3 years for the TIGR mesh, and further studies are needed to investigate if the mesh also completely absorbs in humans.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Primary Osteosarcoma of the Sternum: A case Report and Review of the Literature

Osteosarcoma (osteogenic sarcoma: OS) is the most common primary malignant bone tumor of long bones, whereas primary osteosarcoma of chest wall, especially in sternum, is extremely rare. We report a 57-year-old man with an immobile slow growing mass located in the middle of the sternum. The patient had no significant pain or tenderness and the past medical history was not remarkable. CT-scan sh...

متن کامل

Does Exposure to Static Magnetic Fields Generated by Magnetic Resonance Imaging Scanners Raise Safety Problems for Personnel?

MRI workers are occupationally exposed to static and time-varying gradient magnetic fields.  While the 24-hour time-averaged exposure to static magnetic fields is about a few mT, the maximum static field strength can be as high as 500 mT during patient setup. Over the past several years, our laboratory has performed extensive experiments on the health effects of exposure of animal models and h...

متن کامل

Primary prostate solitary neurofibroma without neurofibromatosis-I: a case report and narrative review of the literature

Neurofibroma of the prostate is an extremely rare benign tumor, particularly when it is not associated with neurofibromatosis-I (NF-1). This study aimed to report the case of a 44-year-old man who presented with dysuria for about 4 years. Magnetic resonance imaging (MRI) showed a mass in the prostate with “target sign” on T2-weighted imaging. The mass was surgically excised, and histopathologic...

متن کامل

Noninvasive Stem Cell Labeling Using USPIO Technique and their Detection with MRI

Background: To date, several imaging techniques to track stem cells are used such as positron emission tomography (PET), single photon emission computed tomography (SPECT), Bioluminescence imaging (BLI), fluorescence imaging, CT scan and magnetic resonance imaging (MRI). Although, overall sensitivity of MRI compared to SPECT and Bioluminescence techniques are lower, but due to high spatial reso...

متن کامل

The Cervical Sequestrated Disc Fragment Presenting as Mass Lesion: Case Report and Review of the Literature

Background & Importance: Disc herniation is defined as the prolapsed of material disc into the spinal canal. If the disc fragment is free in spinal canal, it is called sequestration disc fragment. Occasionally, alteration in sequestration disc fragment makes the diagnosis of the disc herniation, challenging. Case Presentation: We reviewed a rare case of the cervical sequestrated disc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2015  شماره 

صفحات  -

تاریخ انتشار 2015