Gas-chromatographic analysis of mycolic acid cleavage products in mycobacteria.

نویسندگان

  • G O Guerrant
  • M A Lambert
  • C W Moss
چکیده

Mycolic acids were detected in both reference strains and clinical isolates of mycobacteria using gas chromatography of fatty acid methyl esters prepared by acid methanolysis. The methyl esters were extracted with hexane, concentrated, and analyzed with a gas chromatograph by using two different injector temperatures. When the samples were analyzed at high injector temperatures of 300 to 350 degrees C, characteristic thermal cleavage products from mycolic acids, C22:0, C24:0, or C26:0 fatty acid methyl esters, were detected. When analyzed at injector temperatures of 235 degrees C or lower, the mycolic acids were heat stable and the characteristic methyl ester cleavage products were not observed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Capillary gas chromatographic analysis of mycolic acid cleavage products, cellular fatty acids, and alcohols of Mycobacterium xenopi.

The fatty acids, alcohols, and mycolic acids of 26 strains of Mycobacterium xenopi were studied by capillary gas chromatography and thin-layer chromatography. All strains contained alpha-, keto-, and omega-carboxymycolates. The primary mycolic acid cleavage product was hexacosanoic acid. The fatty acid patterns and, especially, the presence of 2-docosanol are characteristic markers of M. xenopi.

متن کامل

Mycolic acids from "noncultivable" mycobacteria.

Chromatographic analysis, coupled to mass spectrometry with a high-resolution mass spectrometer, of materials isolated from skin lesions of patients with lepromatous leprosy allows the recognition of characteristic mycobacterial products, mycolic acids. This finding indicates that the "noncultivable" bacteria responsible for leprosy are mycobacteria.

متن کامل

Improved identification of mycobacteria by using the microbial identification system in combination with additional trimethylsulfonium hydroxide pyrolysis.

The MIDI automated Microbial Identification System (MIS) uses gas chromatography (GC) analysis of whole-cell fatty acid methyl esters (FAMEs) between 9 and 20 carbons in length to characterize a wide range of bacterial genera and species, including mycobacteria. Mycolic acid cleavage products (MACPs) with chain lengths of C22 to C26 are not released by MIDI sample preparation of mycobacteria. T...

متن کامل

Identification of mycobacteria by thin layer chromatographic analysis of mycolic acids and conventional biochemical method: four years of experience.

Mycolic acids analysis by thin-layer chromatography (TLC) has been employed by several laboratories worldwide as a method for fast identification of mycobacteria. This method was introduced in Brazil by our laboratory in 1992 as a routine identification technique. Up to the present, 861 strains isolated were identified by mycolic acids TLC and by standard biochemical tests; 61% out of these str...

متن کامل

Classification of Mycobacteria

Traditional methods have relied on classification based on morphology and enzymatic tests, which are subjective and can be time-consuming (typical turnaround from sample collection to results is measured in weeks). Recently, it has been demonstrated that the fatty acids of the cell walls of these bacteria are diagnostic for some species (1). These fatty acids are mainly comprised of high molecu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 13 5  شماره 

صفحات  -

تاریخ انتشار 1981