PURPOSE The purpose of this study was to compare the mean findings and the repeatability of the minus lens (ML) amplitude of accommodation (AA) at 33 cm and 40 cm. MATERIALS AND METHODS AA was measured from the dominant eye of 120 fully corrected subjects using the ML procedure when viewing the target at both 33 and 40 cm. Each measurement was repeated between 24 and 48 hours after the first trial. RESULTS Mean AA when tested at 33 cm and 40 cm was 10.20 diopter (D) (standard deviation [SD] =1.24) and 8.85 D (SD = 1.23), respectively (P < 0.001). The limits of agreement of the measured amplitude calculated with taking into account of the replicates at 33 and 40 cm were - 0.19 (95% confidence interval [CI]: -0.34 to -0.04) and 2.53 (95% CI: 2.38 to 2.68), respectively. The repeatability of testing at the two distances 33 and 40 cm was ± 1.24 and ± 0.99, respectively. In addition, the retest reliability of measured amplitude using the intraclass correlation coefficient was 0.87 (95% CI: 0.789-0.920) at 33 cm and 0.91 (95% CI: 0.872-0.945) at 40 cm. CONCLUSION There is no agreement in the obtained amplitude at the two measurement distances. Testing the ML AA at 40 cm may be superior given that a lower repeatability coefficient was observed. However, it is unclear whether the larger amplitude measured at 33 cm reflects a larger increase in accommodation (greater proximity effect) or a decrease in the ability to perceive the first slight sustained blur.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Peripheral Design of Progressive Addition Lenses and the Lag of Accommodation in Myopes.

Purpose Insufficient accommodative response is assumed to result in myopia progression. We have investigated if the accommodative lag in myopes is different between a single vision lens (SVL) and the progressive addition lens PAL 2, clinically trialled for its ability to reduce progression of myopia, and if there exist differences in accommodative lag between PAL 2 and other PALs with the same ...

متن کامل

The influence of crystalline lens accommodation on post-saccadic oscillations in pupil-based eye trackers

It is well known that the crystalline lens (henceforth lens) can oscillate (or 'wobble') relative to the eyeball at the end of saccades. Recent research has proposed that such wobbling of the lens is a source of post-saccadic oscillations (PSOs) seen in data recorded by eye trackers that estimate gaze direction from the location of the pupil. Since the size of the lens wobbles increases with ac...

متن کامل

Comparison of three monocular methods for measuring accommodative stimulus–response curves

PURPOSE The aim was to evaluate the repeatability of dynamic measurement of the accommodative stimulus-response curve (ASRC) at three different dioptric speeds using a modified instrument and its agreement with two other methods. METHODS Twenty-nine adults (23.5 ± 2.0 years) were enrolled in the study. ASRC was measured monocularly using three methods: dynamic and static measurement using a m...

متن کامل

Accommodation measurements in a prepresbyopic and presbyopic population.

PURPOSE To study the efficacy of several subjective and objective methods of accommodation measurement in normal prepresbyopic and presbyopic populations to identify appropriate methods for measuring the outcome of accommodative restorative procedures. SETTING University of Houston, College of Optometry, Houston, Texas, USA. METHODS Thirty-one normal subjects with a mean age of 43.7 years (...

متن کامل

Objective accommodative amplitude and dynamics with the 1CU accommodative intraocular lens.

PURPOSE To compare the objective accommodative amplitude and dynamics of eyes implanted with the one-compartment-unit (1CU; HumanOptics AG, Erlangen, Germany) accommodative intraocular lenses (IOLs) with that measured subjectively. METHODS Twenty eyes with a 1CU accommodative IOL implanted were refracted and distance and near acuity measured with a logMAR (logarithm of the minimum angle of re...