Quality factor analysis and optimization of digital filtering signal reconstruction for liquid ionization calorimeters

نویسنده

  • Marco Delmastro
چکیده

The Optimal Filtering (OF) reconstruction of the sampled signals from a particle detector such as a liquid ionization calorimeter relies on the knowledge of the normalized pulse shapes. This knowledge is always imprecise, since there are residual differences between the true ionization pulse shapes and the predicted ones, whatever the method used to model or fit the particle–induced signals. The systematic error introduced by the residuals on the signal amplitude estimate is analyzed, as well as the effect on the quality factor provided by the OF reconstruction. An analysis method to evaluate the residuals from a sample of signals is developed and tested with a simulation tool. The correction obtained is showed to preserve the original amplitude normalization, while restoring the expected χ2–like behavior of the quality factor.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Post-Reconstruction Gaussian Filtering on Image Quality and Myocardial Blood Flow Measurement with N-13 Ammonia PET

Objective(s): In order to evaluate the effect of post-reconstruction Gaussian filtering on image quality and myocardial blood flow (MBF) measurement by dynamic N-13 ammonia positron emission tomography (PET), we compared various reconstruction and filtering methods with image characteristics. Methods: Dynamic PET images of three patients with coronary artery disease (male-female ratio of 2:1; a...

متن کامل

Determination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection

Objective(s): Dispersive liquid-liquid microextraction coupled with gas chromatography (GC)-flame ionization detector was developed for the determination of valproic acid (VPA) in human plasma. Materials and Methods: Using a syringe, a mixture of suitable extraction solvent (40 µl chloroform) and disperser (1 ml acetone) was quickly added to 10 ml of diluted plasma sample containing VPA (pH, 1....

متن کامل

Determination of 2-phenylethanol in Rose Water Using Dispersive Liquid-Liquid Microextraction with Gas Chromatography Flame Ionization Detection

A simple and rapid microextraction procedure based on dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-flame ionization detection (GC-FID) was developed for the extraction and analysis of 2-phenylethanol in rose water sample. In the proposed approach, carbon tetrachloride and ethanol were used as extraction and dispersive solvents, respectively. Some important pa...

متن کامل

Improving adaptive resolution of analog to digital converters using least squares mean method

This paper presents an adaptive digital resolution improvement method for extrapolating and recursive analog-to-digital converters (ADCs). The presented adaptively enhanced ADC (AE-ADC) digitally estimates the digital equivalent of the input signal by utilizing an adaptive digital filter (ADF). The least mean squares (LMS) algorithm also determines the coefficients of the ADF block. In this sch...

متن کامل

Evaluation of the Influence of Exposure Index on Image Quality and Radiation Dose

Introduction: The introduction of digital radiography has led to a significant problem in terms of dose creep. To address this problem, manufacturers have established a set of exposure indicators (EI) as a feedback mechanism to safeguard against overexposure. The EI is the measure of incident exposure to the detector that is directly proportional to the signal-to-noise...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008