Quartz-Crystal Spectrometer for the Analysis of Plutonium K X-Rays
نویسندگان
چکیده
The ability to quickly quantify the Pu content within spent nuclear fuel (SNF) is essential to nuclear forensics. Analysis of the Pu to U ratio can provide information on fuel which could contribute to the attribution of a fuel sample. Plutonium concentration data can be acquired through non-destructive analysis (NDA) by detecting self-induced x-ray fluorescence (XRF) from Pu in the fuel. However, during conventional spectroscopy, the characteristic Pu x-ray peak of interest lies beneath background and requires an extended count time. Crystal spectrometers allow x-rays of selected energies, obeying Bragg’s law for coherent scattering of incident photons, to be focused directly onto a detector. This provides a high signal with limited background by decreasing the possible Compton interaction in the detector. The crystal design and the experimental geometry that would allow for the study of high energy x-rays required further attention. In addition, a preliminary MCNP simulation of the energy-direction coupled photon source from the quartz crystal was used to calculate the improved signal-to-noise ratio of the Pu x-ray peak above background.
منابع مشابه
On the characterisation of a Bragg spectrometer with X-rays from an ECR source
Narrow X-ray lines from helium-like argon emitted from a dedicated ECR source have been used to determine the response function of a Bragg crystal spectrometer equipped with large area spherically bent silicon (111) or quartz (101̄) crystals. The measured spectra are compared with simulated ones created by a ray-tracing code based on the expected theoretical crystal’s rocking curve and the geome...
متن کاملPolarizability and Hyperpolarizability of Schiff Base Salen-H2 as Judged as UV-vis Spectroscopy and Simulation Analysis
The aim of the present study was to evaluate the properties of linear andnonlinear optics of the Schiff base Salen. Crystal structure of nanoparticles wasdetermined by a Bruker make diffractometer, Cu-K X-rays of wavelength (=1.5406Å). The XRD patterns were recorded in the 2 range of 10–90o with a step width of 0.02s-1. The UV-Vis Spectra recorded on a computerized double - beam Shimadzu 255...
متن کاملDesign and performance of a curved-crystal x-ray emission spectrometer.
A curved-crystal x-ray emission spectrometer has been designed and built to measure 2-5 keV x-ray fluorescence resulting from a core-level excitation of gas phase species. The spectrometer can rotate 180 degrees, allowing detection of emitted x rays with variable polarization angles, and is capable of collecting spectra over a wide energy range (20 eV wide with 0.5 eV resolution at the Cl K edg...
متن کاملA high-resolution transmission-type x-ray spectrometer designed for observation of the Ka transitions of highly charged high-Z ions
High-resolution reflection-type crystal spectrometers have been used for x-ray energies up to 13 keV, e.g., the K-shell radiation of heliumlike Kr. In order to extend crystal spectrometer measurements to higher energy x rays from higher-Z elements, we employ the crystal in transmission. The geometry we use is known as DuMond geometry. Using such a transmission-type crystal x-ray spectrometer, w...
متن کاملApplication of characteristic X-rays to measure linear attenuation coefficient of nano-composites used in shielding
Using of X-rays in different industries and especially in medical application is increasing. In this regard, designing of light and efficient protective material based on polymeric nanocomposites and precise study of the effect of adding nanoparticles with different sizes on the X-ray attenuation is necessary. In this study the epoxy nanocomposites with different percentages of copper oxide nan...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2012