Comparison of the EZ-Cap recapper with the Mayo recapper for the prevention of needlesticks.
نویسندگان
چکیده
UNLABELLED The purpose of this project was the development of a device that improves the design of our current capping block, the Mayo recapper. The major challenges for design and improvement included creating a device that is simple to use and can be applied throughout our department. We wanted a recapper device that increased safety and minimized the potential for needlesticks. Simplicity was another important factor, along with versatility and low cost. A new recapper, called EZ-Cap, was developed, and a comparison study was conducted to evaluate the pros and cons of the EZ-Cap recapper and the Mayo recapper. METHODS Nuclear medicine technologists (n = 10) in our department used each device when administering patient injections. At the conclusion of their patient injection rotation, they recorded on a survey sheet the pros and cons of each device. The results of this survey were used to evaluate the effectiveness, comfort level during use, and safety of each recapping device. We used a 2-level scoring system to help determine which device was more favorable. The first level focused on comfort and convenience and was given a score of +1 or -1. The second level focused on safety and was given a score of +2 or -2. Because we believed that safety was a high priority for our capping blocks, this level received a higher score than the first level. RESULTS The Mayo recapper was the device preferred by 9 of 10 technologists surveyed. The EZ-Cap recapper had several technical issues that made it difficult to use and that could potentially lead to safety concerns. According to our scoring system, the Mayo recapper received a score of +9 for its pros and -4 for its cons. By comparison, the EZ-Cap recapper received a score of +7 for its pros and -16 for its cons. CONCLUSION Our results show that the Mayo recapper was the device of choice because its pros outweighed its cons. However, we will continually improve the effectiveness of the Mayo recapper to prevent needlesticks.
منابع مشابه
Measurement and comparison of head scatter factor for 9MV photon beam using the build-up cap and a columnar mini-phantom
Introduction: The Sc is an important parameter to monitor unit (MU) calculation in radiation therapy procedure. The aim of this study is to measurement and comparison of head scatter factor (Sc) for 9MV photon beam using the build-up cap and a columnar mini-phantom. Materials and Methods: The measurements performed using a calibrated ion chamber (Scanditron...
متن کاملبررسی مقایسهای دقت دستگاه Neosono Ultima EZ و رادیوگرافی و یک دستگاه اپکسیاب آزمایشی در تعیین طول کانال ریشه
Statement of Problem:Various methods have already been suggested to measure the working length in root canal therapy among which the use of paper point, tactile sense, radiography and electronic apex finder instruments can be named. Investigations on EAL (Electronic Apex Locator) indicate that these instruments can reduce the number of required radiography to a great extent. Moreover, in speci...
متن کاملPre-travel Health Care Utilization Among Travelers Who Visit Friends and Relatives
Introduction: Immigrants to the United States who return home to visit friends and relatives (VFRs) have high rates of travel-related infections. The data on VFR utilization of pre-travel health care is inadequate. The objective of this study was to describe the travel patterns and adherence to pre-travel recommendations of VFRs.Methods: This retrospectiv...
متن کاملSignificance of Perioperative Tests to Diagnose the Infection in Revision Total Shoulder Arthroplasty
Background: The purpose of this study was to evaluate the value of perioperative tests for the diagnosis of infectionin revision shoulder arthroplasty.Methods: A retrospective analysis was performed on 537 shoulder arthroplasties (429 patients) that underwent revisionshoulder arthroplasty at our institution. Periprosthetic tissue cultures were positive in 169/537 surgeries.Results: White-blood ...
متن کاملComparison of the Pediatric Cochlear Implantation Using Round Window and Cochleostomy
Introduction: Cochlear implantation (CI) is now regarded as a standard treatment for children with severe to profound sensor neural hearing loss. This study aimed to compare the efficacy of the round window approach (RWA) and standard cochleostomy approach (SCA) in the preservation of residual hearing after CI in pediatric patients. Materials and Methods: This double-blind ran...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine technology
دوره 36 3 شماره
صفحات -
تاریخ انتشار 2008