Efficacy of metered-dose inhaler administration of albuterol in intubated infants.
نویسندگان
چکیده
STUDY OBJECTIVE To compare the safety and efficacy of metered-dose inhaler (MDI) albuterol to nebulized (NEB) albuterol administration. DESIGN A randomized, triple-blinded, crossover study. SETTING A pediatric ICU in a tertiary care children's hospital. PATIENTS Eleven intubated infants with bronchiolitis. INTERVENTIONS Subjects received four puffs of MDI albuterol (360 microg) and 3 mL of NEB saline solution placebo or 0.3 mL of NEB albuterol (1.5 mg) and MDI saline solution placebo. Each set of albuterol and saline solution placebo was administered after direct attachment of delivery device to the endotracheal tube and bag-valve system. Subjects received the opposite sequence 4 h after the initial sequence. The second sequence was given first the next day, and the first sequence was administered 4 h later. MEASUREMENTS AND RESULTS Respiratory system compliance and resistance were measured at baseline and 30 min, 1 h, 2 h, and 4 h after each set of placebo and albuterol. There was an appreciable improvement in compliance and resistance for up to 2 h following both methods of administration. However, the degree of improvement was not significantly different (p>0.05) between the two methods. Neither method caused a significant change in resistance when measured at 4 h after albuterol/placebo administration. No evidence of toxicity was detected. CONCLUSIONS MDI-administered albuterol is as safe and efficacious as nebulized-administered albuterol in intubated infants with bronchiolitis. Generalizability of these results is limited by differences in drug delivery with different brands of nebulizers and spacers and sites of attachment.
منابع مشابه
Two administration methods for inhaled salbutamol in intubated patients.
AIMS To compare serum concentrations and effects on respiratory mechanics and haemodynamics of salbutamol administered by small volume nebuliser (SVN) and metered dose inhaler (MDI) plus spacer. METHODS Blinded, randomised, crossover study in 12 intubated infants and children (mean age 17.8 months) receiving inhaled salbutamol therapy. Subjects received salbutamol as 0.15 mg/kg by SVN and fou...
متن کاملDelivery of salbutamol by metered dose inhaler and valved spacer to wheezy infants: effect on bronchial responsiveness.
The efficacy of a new valved spacer device, the Babyhaler inhaler (Glaxo) for administering metered dose inhaler treatment via a facemask to infants was assessed. In a double blind, single dose study, salbutamol (800 micrograms) or placebo were given on separate days to 12 sedated, sleeping, wheezy infants during a symptom free interval. Lung function was measured before and after administratio...
متن کاملTreatment of bronchospasm by metered-dose inhaler albuterol in mechanically ventilated patients.
beta 2-agonist bronchodilators delivered by metered-dose inhalers (MDI) are commonly used in the treatment of bronchospasm in both intubated and nonintubated patients. Substantial data support the effectiveness of MDI delivery systems in nonintubated patients. However, few studies have examined the effectiveness of MDIs in intubated, mechanically ventilated patients. MDIs are often used in conj...
متن کاملEfficacy of inhaled corticosteroids in infants and preschoolers with recurrent wheezing and asthma: a systematic review with meta-analysis.
OBJECTIVE To compare the efficacy of inhaled corticosteroids in infants and preschoolers with recurrent wheezing or asthma. METHODS Randomized, prospective, controlled trials published January 1996 to March 2008 with a minimum of 4 weeks of inhaled corticosteroids versus placebo were retrieved through Medline, Embase, and Central databases. The primary outcome was wheezing/asthma exacerbation...
متن کاملA comparison of metered-dose inhaled albuterol versus endotracheal liquid bolus albuterol for the treatment of bronchoconstriction.
INTRODUCTION Aerosolized albuterol delivery is a mainstay treatment for bronchoconstriction; however, almost no data exist that evaluate the clinical outcome of instillation of an endotracheal liquid bolus (ELB) of a bronchodilator directly into the airway. METHODS This randomized trial sought to evaluate the efficacy of albuterol lavage via artificial airway with accompanied patient position...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chest
دوره 112 2 شماره
صفحات -
تاریخ انتشار 1997