Regularized Iterative Weighted Filtered Back-Projection for Few-View Data Photoacoustic Imaging

نویسندگان

  • Xueyan Liu
  • Dong Peng
چکیده

Photoacoustic imaging is an emerging noninvasive imaging technique with great potential for a wide range of biomedical imaging applications. However, with few-view data the filtered back-projection method will create streak artifacts. In this study, the regularized iterative weighted filtered back-projection method was applied to our photoacoustic imaging of the optical absorption in phantom from few-view data. This method is based on iterative application of a nonexact 2DFBP. By adding a regularization operation in the iterative loop, the streak artifacts have been reduced to a great extent and the convergence properties of the iterative scheme have been improved. Results of numerical simulations demonstrated that the proposed method was superior to the iterative FBP method in terms of both accuracy and robustness to noise. The quantitative image evaluation studies have shown that the proposed method outperforms conventional iterative methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Limited-view photoacoustic imaging based on an iterative adaptive weighted filtered backprojection approach.

An iterative adaptive weighted filtered backprojection (FBP) approach was applied to our photoacoustic imaging (PAI) of the optical absorption in biological tissues from limited-view data. By using an image-based adaptive weighted PAI reconstruction, we can modify the defect of the artifacts degrading the quality of the image. Results of numerical simulations demonstrated that the proposed algo...

متن کامل

Comparisons of Hounsfield Unit Linearity between Images Reconstructed using an Adaptive Iterative Dose Reduction (AIDR) and a Filter Back-Projection (FBP) Techniques

Background: The HU linearity is an essential parameter in a quantitative imaging and the treatment planning systems of radiotherapy. Objective: This study aims to evaluate the linearity of Hounsfield unit (HU) in applying the adaptive iterative dose reduction (AIDR) on CT scanner and its comparison to the filtered back-projection (FBP).Material and Methods: In this experimental phan...

متن کامل

Low-Dose Micro-CT Imaging for Vascular Segmentation and Analysis Using Sparse-View Acquisitions

The aim of this study is to investigate whether reliable and accurate 3D geometrical models of the murine aortic arch can be constructed from sparse-view data in vivo micro-CT acquisitions. This would considerably reduce acquisition time and X-ray dose. In vivo contrast-enhanced micro-CT datasets were reconstructed using a conventional filtered back projection algorithm (FDK), the image space r...

متن کامل

Fast System Matrix Calculation in CT Iterative Reconstruction

Introduction: Iterative reconstruction techniques provide better image quality and have the potential for reconstructions with lower imaging dose than classical methods in computed tomography (CT). However, the computational speed is major concern for these iterative techniques. The system matrix calculation during the forward- and back projection is one of the most time- cons...

متن کامل

Comparing IDREAM as an Iterative Reconstruction Algorithm against In Filtered Back Projection in Computed Tomography

Introduction: Recent studies of Computed Tomography (CT) conducted on patient dose reduction have recommended using an iterative reconstruction algorithm and mA (mili-Ampere) dose modulation. The current study aimed to evaluate Iterative Dose Reduction Algorithm (IDREAM) as an iterative reconstruction algorithm. Material and Methods: Two CT p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2016  شماره 

صفحات  -

تاریخ انتشار 2016