Comparison of the CT scatter fractions provided in NCRP Report No. 147 to scanner-specific scatter fractions and the consequences for calculated barrier thickness.

نویسندگان

  • Sandra C Larson
  • Mitchell M Goodsitt
  • Emmanuel G Christodoulou
  • Lloyd S Larson
چکیده

The new NCRP Report No. 147 includes methodology to determine x-ray protective shielding for CT scanner rooms. This methodology assumes fixed values of the scatter fraction per centimeter (kappa) for the peripheral axis of the head and body CT phantoms. An investigation was performed to determine kappa for different makes and models of CT scanner and examine the consequences of the differences between these and the fixed NCRP values on a typical shielding calculation. kappa values were calculated using an equation for the scattered air kerma at 1 m from NCRP 147 (Kerma(scatter) = kappa x ScanLength x CTDI(100) x pitch(-1)) and using scattered air kerma data provided by the manufacturers and measured CTDI(100) (periphery) values. Typical barrier calculations, following NCRP 147 methodology, were performed for each CT scanner using the fixed kappa values and, separately, using the calculated scanner-specific values. Ten CT scanner models from three manufacturers were investigated. The calculated scanner-specific kappa values varied from the NCRP fixed values by as much as 82%. However, when these kappa values were used in typical barrier calculations, the final shielding requirements using the NCRP fixed values were 0.5 to 13% less than those using the scanner specific values. It is likely that such small underestimates in the shielding requirement due to using the NCRP fixed kappa values would be more than compensated by the conservative assumptions that are incorporated in a typical barrier calculation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Shielding evaluation of a typical radiography department: a comparison between NCRP reports No.49 and 147

Background: Designing and shielding of an appropriate radiography room has been one of the major concerns of radiation scientists since the first decade after the invention of X-rays. Recently, report No.147 of National Council on Radiation Protection and Measurements (NCRP) has been published. In this study the researchers have investigated the effect of new report recommendation on primary an...

متن کامل

Performance comparison of four commercial GE discovery PET/CT scanners: A monte carlo study using GATE

  Combined PET/CT scanners now play a major role in medicine for in vivo imaging in oncology, cardiology, neurology, and psychiatry. As the performance of a scanner depends not only on the scintillating material but also on the scanner design, with regards to the advent of newer scanners, there is a need to optimize acquisition protocols as well as to compare scanner ...

متن کامل

Calculation of the Scattered Radiation Profile in 64 Slice CT Scanners Using Experimental Measurement

Introduction: One of the most important parameters in x-ray CT imaging is the noise induced by detected scattered radiation. The detected scattered radiation is completely dependent on the scanner geometry as well as size, shape and material of the scanned object. The magnitude and spatial distribution of the scattered radiation in x-ray CT should be quantified for development of robust scatter...

متن کامل

Treatment vault shielding for a flattening filter-free medical linear accelerator.

The requirements for shielding a treatment vault with a Varian Clinac 2100 medical linear accelerator operated both with and without the flattening filter were assessed. Basic shielding parameters, such as primary beam tenth-value layers (TVLs), patient scatter fractions, and wall scatter fractions, were calculated using Monte Carlo simulations of 6, 10 and 18 MV beams. Relative integral target...

متن کامل

Comparison of different methods for shielding design in computed tomography.

The purpose of this work is to compare different methods for shielding calculation in computed tomography (CT). The BIR-IPEM (British Institute of Radiology and Institute of Physics in Engineering in Medicine) and NCRP (National Council on Radiation Protection) method were used for shielding thickness calculation. Scattered dose levels and calculated barrier thickness were also compared with th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Health physics

دوره 93 2  شماره 

صفحات  -

تاریخ انتشار 2007