Determination of trace perchlorate in water: a simplified method for the identification of potential interferences
نویسندگان
چکیده
Background: Perchlorate contamination of water and food poses potential health risks to humans due to the possible interference of perchlorate with the iodide uptake into the thyroid gland. Perchlorate has been found in food and drinking, surface, or swimming pool waters in many countries, including the United States, Canada, France, Germany, and Switzerland, with ion chromatography (IC) being the preferred analytical method. The standardization of a robust ion chromatographic method is therefore of the high interest for public health and safety. This article summarizes the experiments and results obtained from analyzing untreated samples, considering the sample’s electrical conductance as guidance for direct sample injection as described in EPA 314.0. Results: The suitability of ion chromatography with suppressed conductivity detection was tested for water samples in order to check the influence of matrix effects on the perchlorate signal of untreated samples. A sample injection volume of 750 μL was applied to the selected 2 mm IC column. The IC determination of perchlorate at low μg/L levels is challenged by the presence of high loads of matrix ions (e.g., chloride, nitrate, carbonate, and sulfate at 100 mg/L and above). Perchlorate recovery is impaired with the increasing matrix ion concentrations, and its chromatographic peak is asymmetric particularly at low perchlorate concentrations. The identification of the individual maximum concentration of interfering anions like chloride, nitrate, and sulfate that influence perchlorate recovery helps to reduce the number of sample preparation steps or an obligatory measurement of the electrical conductivity of the sample. Within the scope of this study, samples containing less than 125 mg/L of either anion did not need sample preparation. Conclusion: The identification of the maximum concentration of interfering anions like chloride, nitrate, and sulfate influencing perchlorate recovery provides a simplified alternative to the EPA 314.0 method. This approach reduces unnecessary sample preparation steps while allowing a reliable prognosis of possible interferences and maintaining result quality. This study was performed to support the development of a respective international standard, which is being established by the International Organization for Standardization (ISO). The results of the study are also intended to be used as guidance for interested laboratories to optimize the analytical workflow for trace perchlorate
منابع مشابه
A Facile Catalytic- Kinetic Method for The Determination of Selenium (IV)
A catalytic-kinetic method for the determination of selenium is proposed. Alizarin navy blue is reduced by sodium sulfide to from a colorless product. The reaction is accelerated by trace amounts of Se (IV), and can be followed by measuring the decrease in absorbance of the dye at 620nm and 30 °C by the fixed time method. Selenium can be determined in the range of 0.004 — 0.12 1.1g.m1-1 . ...
متن کاملValidation data for the determination of perchlorate in water using ion chromatography with suppressed conductivity detection
BACKGROUND Perchlorate salts are relatively stable, soluble in water, and migrate into groundwater sources. Groundwater is an essential source for drinking water suppliers. Perchlorate bears health risks as it is identified to impair normal thyroid function by interfering with iodine uptake by the thyroid gland. The development of a sensitive analytical method for the determination of perchlora...
متن کاملEnrichment of trace amounts Nickel (П) in water samples using nano-Fe3O4-encapsulated-dioctylphthalate and linked- ethylenediamine
A simple, highly sensitive, accurate and selective method for determination of trace amounts of Ni2+ in water samples. In this paper, Dioctylphthalate (DOP) was used to encapsulate nano-Fe3O4 and produce a nano-Fe3O4-DOP sorbent based new sorbent was prepared. This was treated with ethylenediamine (ED) in another solvent-free procedure for the formation of a novel nano-Fe3O4-DOP-ED. Flame atomi...
متن کاملEnrichment of trace amounts Nickel (П) in water samples using nano-Fe3O4-encapsulated-dioctylphthalate and linked- ethylenediamine
A simple, highly sensitive, accurate and selective method for determination of trace amounts of Ni2+ in water samples. In this paper, Dioctylphthalate (DOP) was used to encapsulate nano-Fe3O4 and produce a nano-Fe3O4-DOP sorbent based new sorbent was prepared. This was treated with ethylenediamine (ED) in another solvent-free procedure for the formation of a novel nano-Fe3O4-DOP-ED. Flame atomi...
متن کاملSpectrophotometric determination of trace amount of malachite green from water with novel magnetic silica nanoparticles
A nano-hybrid based on polystyrene derivatives and magnetite was introduced as a new sorbent for pretreatment and determine the trace amount of malachite green from aqueous solution by spectrophotometry after preconcentration by solid phase extraction (SPE). UV–Vis spectrophotometer was used for determination of MG concentration after desorption of the dye by hydrochloric acid solution in the s...
متن کامل