Tissue dielectric constant (TDC) as an index of localized arm skin water: differences between measuring probes and genders.

نویسندگان

  • H N Mayrovitz
  • D N Weingrad
  • F Brlit
  • L B Lopez
  • R Desfor
چکیده

An easily measured, non-invasive, quantitative estimate of local skin tissue water is useful to assess local lymphedema and its change. One method uses skin tissue dielectric constant (TDC) values that at 300 MHz TDC depend on free and bound water within the measurement volume. In practice such measurements have been done with a research-type multi-probe, but recently a hand-held compact-probe has become available that may be more clinically convenient. Because most available published data is based on multiprobe measurements it is important to characterize possible differences between devices that unless known might lead to ambiguous quantitative comparisons between TDC values. Thus, our purpose was to evaluate potential differences in measured TDC values between multi-probe and compact-probe devices with respect to probe effective sampling depth, anatomical site, and gender and also to compare compact-probe TDC values measured on women with and without breast cancer (BC). TDC was measured bilaterally on forearms and biceps of 32 male and 32 female volunteers and on 12 female patients awaiting surgery for breast cancer. Results show that 1) TDC values at 2.5 mm depth were significantly less than at 1.5 mm; 2) Female TDC values were significantly less than male values; 3) TDC values were not different between females with and without BC; and 4) dominant/non-dominant arm TDC ratios were not significantly different for any probe among genders or arm anatomical site. These findings indicate that probe type differences in absolute TDC values are present and should be taken into account when TDC values are compared. However, comparisons based on inter-arm TDC ratios are not statistically different among probes with respect to gender or anatomical location.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Race-related differences in tissue dielectric constant measured noninvasively at 300 MHz in male and female skin at multiple sites and depths.

BACKGROUND/PURPOSE We hypothesized that reported race-related differences in skin properties cause skin and skin-to-fat water differences among races that are measureable by skin tissue dielectric constant (TDC) values that depend strongly on water content. Our first aim was to test this hypothesis. Also, since inter-side TDC ratios are used to assess edema and lymphedema, the second aim was to...

متن کامل

Tissue dielectric constant (TDC) measurements as a means of characterizing localized tissue water in arms of women with and without breast cancer treatment related lymphedema.

Quantitative measurements to detect lymphedema early in persons at-risk for breast cancer (BC) treatment-related lymphedema (BCRL) can aid clinical evaluations. Since BCRL may be initially manifest in skin and subcutis, the earliest changes might best be detected via local tissue water (LTW) measurements that are specifically sensitive to such changes. Tissue dielectric constant (TDC) measureme...

متن کامل

Gender differences in facial skin dielectric constant measured at 300 MHz.

BACKGROUND/PURPOSE Skin tissue dielectric constant (TDC) measurements at 300 MHz provide non-invasive data on free and bound tissue water. TDC-data is available for some body sites, but most is for female forearm. Contrastingly, there are no data on face-skin or comparative data between genders. Our goals were to obtain facial-TDC reference values and determine if TDC-values differ between gend...

متن کامل

Assessing local tissue edema in postmastectomy lymphedema.

Overall limb lymphedema can be assessed by several methods but none are suitable to determine local edema. Quantifying local edema could provide important information not previously available. Our goal was to determine the suitability of using the tissue dielectric constant (TDC) as and index of local tissue water to detect and quantify edema in postmastectomy patients with unilateral arm lymph...

متن کامل

Patterns of temporal changes in tissue dielectric constant as indices of localized skin water changes in women treated for breast cancer: a pilot study.

BACKGROUND Our goal was to characterize temporal patterns of skin Tissue Dielectric Constant (TDC) as a foundation for possible TDC use to detect and quantify lymphedema. Although limb volumes and bioimpedance analysis (BIA) are used for this purpose, potential TDC-method advantages are that it can be done in about 10 seconds at any body site to depths from 0.5 to 5.0 mm below the epidermis. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lymphology

دوره 48 1  شماره 

صفحات  -

تاریخ انتشار 2015