Peripheral chemoresponses of infants measured by a minimally invasive method utilizing two-breath alternations in Fl,02.

نویسندگان

  • D A Thomas
  • K Poole
  • E K McArdle
  • C S Beardsmore
  • P C Goodenough
  • J Thompson
  • H Simpson
چکیده

The aim of this study was to develop a minimally invasive and reliable method for measuring peripheral chemoresponsiveness to oxygen in infants, and to establish baseline data from normal infants at 12 weeks of age. Two-breath alternations in fractional inspired oxygen (FI,O2), switching between 0.42 to 0.00 were given for 2 min periods via a face mask (held close to the face but without contact) to 18 healthy infants during quiet sleep. End-tidal oxygen concentrations alternated between 21 and 11%. Instantaneous minute ventilation (V'E) and its components tidal volume (VT), respiratory frequency (fR) inspiratory and expiratory times (tI and tE), inspiratory flow (VT/tT), and inspiratory duty cycle (tI/ttot) were measured by respiratory inductance plethysmography. Two-breath alternations in each of the ventilatory components were matched with the corresponding alternating end-tidal oxygen record and compared with contiguous pre- and post-test data obtained in control periods of air breathing. Alternations in all ventilatory components except fR changed significantly during FI,O2 alternations; VT 26%, tE-8%, VT/tI 18%, tI/ttot 11% and V'E 28% of baseline values. Within and between infant variances are reported for the individual components of ventilation. Differences among infants were best detected by alternations in V'E; within infant variance 76, between infant variance 171. We conclude that the test described is a safe, reliable and relatively easily applied method of measuring peripheral chemoresponsiveness, which is suitable for clinical application in infancy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of sleep deprivation on sleep states, breathing events, peripheral chemoresponsiveness and arousal propensity in healthy 3 month old infants.

We wished to investigate the effects of sleep deprivation on sleep, arousal propensity, respiratory events and peripheral chemoresponses in healthy infants, since these effects might be relevant to mechanisms concerned with some cases of sudden infant death syndrome. Paired observations were made overnight during natural sleep and following sleep deprivation, in a randomized fashion, in 15 heal...

متن کامل

Hyperglycemia and antibody titres against heat shock protein 27 in traumatic brain injury patients on parenteral nutrition

Objective(s):Hyperglycemia worsens the neuronal death induced by cerebral ischemia. Previous studies demonstrated that diabetic hyperglycemia suppressed the expression of heat shock protein 70 and 60 (HSP70 and 60) in the liver. IgG antibody titres against heat shock protein 27 (anti HSP27) were measured to determine whether hyperglycemia exacerbates ischemic brain damage by suppressing the exp...

متن کامل

Evaluation of procalcitonin as a biomarker of diagnosis, severity and postoperative complications in adult patients with acute appendicitis

  Background :Delay in diagnosis and treatment of acute appendicitis (AA) results in an increased rate of perforation, postoperative morbidity, mortality and hospital length of stay. Several biochemical parameters including white blood cell (WBC) count, C-reactive protein (CRP), interleukin-6 (IL6) and Procalcitonin (PCT) have been used to further improve the clinical diagnosis of AA. The aim o...

متن کامل

Audit of Minimally Invasive Hysterectomy Rates: A Canadian Retrospective Cross-Sectional Database Review

Background: Minimally invasive hysterectomy is generally preferable to abdominal hysterectomy. The technicity index (TI) is the proportion of hysterectomies performed by minimally invasive surgery. Many centers globally have started to audit local TI as a quality indicator, but only a handful have published their results to help define international standards of care. <st...

متن کامل

Minimally Invasive Repair of Acute Achilles Tendon Rupture Using Gift Box Technique

Background: This study aimed to introduce a modified technique for minimally invasive Achilles tendon (AT) rupture repairusing gift box sutures. The preliminary clinical and functional outcomes were investigated among a number of patients.Methods: In a consecutive case series study, 24 patients with acute AT rupture underwent modified minimally invasiveAT repair using two mini...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 9 6  شماره 

صفحات  -

تاریخ انتشار 1996