PURPOSE To assess the effect of overnight wear of a contact lens-based sensor (CLS) for monitoring of 24-hr intraocular pressure (IOP) fluctuations on central corneal thickness (CCT). MATERIALS AND METHODS  Changes in the CCT, mid-peripheral corneal thickness and central corneal radius (CCR) during overnight CLS wear in 20 eligible patients with ocular hypertension or established glaucoma were prospectively studied using ultrasound pachymetry and topography. Corneal thickness and CCR changes were evaluated from pre-to-postsleep, with the fellow eye as control. Paired t-test or Wilcoxon signed-rank test was used as appropriate and with α = 0.05. Relationship between the IOP profile recorded by the CLS and the pre-to-postsleep corneal thickness differences was assessed using the Spearman correlation coefficient. RESULTS After CLS wear, mean CCT had changed from 523 to 537 μm (p = 0.015) in the study eye and from 518 to 522 (p = 0.206) in the fellow eye (n = 15). There was no difference in CCT change between eyes (p = 0.075). There were no statistically significant changes in horizontal or vertical CCR in either eye (p > 0.05 for all). No correlation was found between the pre-to-postsleep differences in the CLS signal and the pre-to-postsleep differences in ultrasound CCT measurements (p = 0.974). CONCLUSION The continuous IOP monitoring does not appear to be affected by differences in corneal thickness that occur during overnight CLS wear, although the CLS did induce some corneal swelling. This effect was not statistically significantly different from the control eye and does not seem to influence the CLS IOP profile.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Corneal swelling response to contact lenses worn under extended wear conditions.

Corneal thickness changes were monitored in ten subjects (1) over a 36-hour period without contact lens wear and (2) during 7 days continuous wear of three types of hydrogel contact lenses of different back vertex powers. Measured on awakening, the mean overnight central corneal edema without lenses was 3.0% ± 1.2%. With the lenses used in this study, the mean overnight corneal swelling over th...

متن کامل

Differences between overnight and long-term wear of orthokeratology contact lenses in corneal contour, thickness, and cell density.

PURPOSE To investigate changes in corneal topography and morphology in human eyes wearing orthokeratology (OK) lenses for overnight and over a 5-year period. MATERIALS AND METHODS Fifty-six adults with moderate myopia were assigned to 2 groups based on age matching: 5-year lens wear (n = 26, 51 eyes) and 1-night lens wear (n = 30, 60 eyes). All subjects wore reverse-geometry OK lenses with th...

متن کامل

Topographical thickness of the epithelium and total cornea after overnight wear of reverse-geometry rigid contact lenses for myopia reduction.

PURPOSE To investigate topographical thickness changes of the epithelium and total cornea measured with optical coherence tomography (OCT) after overnight wear of rigid gas-permeable lenses. METHODS Reverse geometry design CRT (Dk=100) rigid (test) lenses (Paragon Vision Sciences, Mesa, AZ) were randomly fitted on one eye of each of 20 neophyte subjects (mean age, 24.6 +/- 2.7 years) and the ...

متن کامل

Vertical and horizontal thickness profiles of the corneal epithelium and Bowman's layer after orthokeratology.

PURPOSE To investigate thickness profile changes of the corneal epithelium and Bowman's layer at the vertical and horizontal meridians with overnight myopia orthokeratology (OK) lenses. METHODS Twenty subjects (age range: 19-33 years) wore reverse-geometry rigid gas-permeable OK lenses in both eyes for 30 days. Before lens wear and after 1, 7, and 30 days of overnight lens wear, evaluation of...

متن کامل

Critical oxygen levels to avoid corneal edema for daily and extended wear contact lenses.

The relationship between corneal edema and hydrogel lens oxygen transmissibility was examined for both daily and extended contact lens wear by measuring the corneal swelling response induced by a variety of contact lenses over a 36-hr wearing period. The relationships derived enable average edema levels that occur with daily and extended wear in a population of normal young adults to be predict...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta ophthalmologica

دوره 90 7  شماره 

صفحات  -

تاریخ انتشار 2012