Fan-Shaped Complete Block on Helical Tomotherapy for Esophageal Cancer: A Phantom Study
نویسندگان
چکیده
Radiation pneumonitis (RP) is a common complication for radiotherapy of esophageal cancer and is associated with the low dose irradiated lung volume. This study aims to reduce the mean lung dose (MLD) and the relative lung volume at 20 Gy (V 20) and at low dose region using various designs of the fan-shaped complete block (FSCB) in helical tomotherapy. Hypothetical esophageal tumor was delineated on an anthropomorphic phantom. The FSCB was defined as the fan-shaped radiation restricted area located in both lungs. Seven treatment plans were performed with nonblock design and FSCB with different fan angles, that is, from 90° to 140°, with increment of 10°. The homogeneous index, conformation number, MLD, and the relative lung volume receiving more than 5, 10, 15, and 20 Gy (V 5, V 10, V 15, and V 20) were determined for each treatment scheme. There was a substantial reduction in the MLD, V 5, V 10, V 15, and V 20 when using different types of FSCB as compared to the nonblock design. The reduction of V 20, V 15, V 10, and V 5 was 6.3%-8.6%, 16%-23%, 42%-57%, and 42%-66% for FSCB 90°-140°, respectively. The use of FSCB in helical tomotherapy is a promising method to reduce the MLD, V 20, and relative lung volume in low dose region, especially in V 5 and V 10 for esophageal cancer.
منابع مشابه
An Attempted Substitute Study of Total Skin Electron Therapy Technique by Using Helical Photon Tomotherapy with Helical Irradiation of the Total Skin Treatment: A Phantom Result
An anthropomorphic phantom was used to investigate a treatment technique and analyze the dose distributions for helical irradiation of the total skin (HITS) by helical tomotherapy (HT). Hypothetical bolus of thicknesses of 0, 10, and 15 mm was added around the phantom body to account for the dose homogeneity and setup uncertainty. A central core structure was assigned as a "complete block" to f...
متن کاملPerformance Characteristics of an Independent Dose Verification Program for Helical Tomotherapy
Helical tomotherapy with its advanced method of intensity-modulated radiation therapy delivery has been used clinically for over 20 years. The standard delivery quality assurance procedure to measure the accuracy of delivered radiation dose from each treatment plan to a phantom is time-consuming. RadCalc®, a radiotherapy dose verification software, has released specifically for beta testing a m...
متن کاملAnalysis of peripheral doses for base of tongue treatment by linear accelerator and helical TomoTherapy IMRT
The purpose of this study was to compare the peripheral doses to various organs from a typical head and neck intensity-modulated radiation therapy (IMRT) treatment delivered by linear accelerator (linac) and helical TomoTherapy. Multiple human CT data sets were used to segment critical structures and organs at risk, fused and adjusted to an anthropomorphic phantom. Eighteen contours were design...
متن کاملThe evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy
Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...
متن کاملRadiotherapy for inoperable non-small cell lung cancer using helical tomotherapy.
AIM To investigate the impact of tomotherapy on the dose delivered to the lungs and other normal tissues. MATERIAL AND METHODS From February 2008 to May 2009, 35 patients with stage IIIA/IIIB non-small cell lung cancer were treated with helical tomotherapy at the S. Camillo-Forlanini Hospital. For our study we selected 20 patients who underwent chemotherapy followed by sequential radiotherapy...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2015 شماره
صفحات -
تاریخ انتشار 2015