Screen Printed Potentiometric Chloride Sensors

نویسندگان

  • Andy Cranny
  • Nick Harris
  • Neil White
چکیده

Potentiometric chloride sensors were fabricated by electrochemically chloridizing the surface of screen printed silver electrodes using amperostatic coulometry or asymmetric square wave voltammetry. In the case of coulometric chloridization, the effect of different chloride ion sources was also investigated. The response to chloride ions by each type of sensor was determined by measuring their potentials with respect to a commercial Ag/AgCl reference electrode over the chloride concentration range 1.8 to 3,545 mg/L (approximately 50 μM to 100 mM). Results reveal that irrespective of fabrication method, all sensors exhibit near Nernstian responses with no significant relationships between fabrication and response parameters. © 2014 The Authors. Published by Elsevier Ltd. Peer-review under responsibility of the scientific committee of Eurosensors 2014.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...

متن کامل

Development of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...

متن کامل

Spray-coated all-solid-state potentiometric sensors.

A novel fully spray coating-based method of the preparation of all-solid-state ion-selective electrodes of simplified construction is proposed. This method is an alternative for screen-printed electrodes used sometimes in potentiometric applications. The benefits of the herein-proposed approach include fully automatic sensor preparation and minimized use of chemicals allowing for the production...

متن کامل

Development of Novel Potentiometric Sensors for Determination of Lidocaine Hydrochloride in Pharmaceutical Preparations, Serum and Urine Samples

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations and biological fluids (urine and serum). It was based on potentiometric titration of...

متن کامل

CO2 Selective Potentiometric Sensor in Thick-film Technology

A potentiometric sensor device based on screen-printed Nasicon films was investigated. In order to transfer the promising sensor concept of an open sodium titanate reference to thick film technology, "sodium-rich" and "sodium-poor" formulations were compared. While the "sodium-rich" composition was found to react with the ion conducting Nasicon during thermal treatment, the "sodium-poor" refere...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014