In the PHENIX experiment at RHIC, the electro-magnetic calorimeter plays an important role in both the heavy-ion and spin physics programs for which it was designed. In order to measure its performance in the energy range up to 80GeV, a beam test was performed at the CERN-SPS H6 beam line. We describe the beam test and present results on calorimeter performance with pion and electron beams.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect on a Hadron Shower Leakage on the Energy Response and Resolution of Hadron TILE Calorimeter

The hadronic shower longitudinal and lateral leakages and its effect on the pion response and energy resolution of ATLAS ironscintillator barrel hadron prototype calorimeter with longitudinal tile configuration with a thickness of 9.4 nuclear interaction lengths have been investigated. The results are based on 100 GeV pion beam data at incidence angle Θ = 10 at impact point Z in the range from ...

متن کامل

Analyses of test beam data using the CALICE calorimeter

We discuss several features of hadronic showers recorded in the high granularity CALICE Si-W ECAL and scintillator-tile HCAL and confront them with several Geant4 physics models. The first measurements of the time-structure of hadronic showers in a tungsten scintillator calorimeter are presented. The high granularity of the CALICE calorimeters allows a software compensation which improves the e...

متن کامل

s . in s - de t ] 1 1 Ju n 20 14 Performance of the first prototype of the CALICE scintillator strip electromagnetic calorimeter The CALICE Collaboration

A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45×10×3 mm plastic scintillator strips. Data were collected using a positron test beam at DESY with momenta between 1 and 6 GeV/c. The prototype’s performance is presented in terms of the linearity and resolution of the energy

متن کامل

Study of Hadronic and Electromagnetic Shower Development between 10 and 140 Gev by an Iron - Scintillator Calorimeter

Results are presented on the analysis of CDHS test beam data using an iron-scintillator calorimeter exposed to electrons and pions in the energy range 10 to 140 GeV. Shower development is studied in order to extract information on calorimetric response to electrons and pions, longitudinal and transverse shower profiles, shower containment and correlations, muon punch through and the effect on e...

متن کامل

Influence of radiation damage on the performance of a lead/scintillator calorimeter investigated with 1–6GeV electrons

The influence of radiation damage on energy resolution, linearity and uniformity of an electromagnetic lead/scintillator calorimeter was studied experimentally with 1–6GeV electrons. Plastic scintillators and wavelength shifter bars were irradiated uniformly with γ rays. Both were identical with those of the ZEUS uranium calorimeter. The attenuation length of the scintillators was determined fr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002