Quantification of [11C]-meta-hydroxyephedrine uptake in human myocardium
نویسندگان
چکیده
BACKGROUND The aims of this study were to determine the optimal tracer kinetic model for [(11)C]-meta-hydroxyephedrine ([(11)C]HED) and to evaluate the performance of several simplified methods. METHODS Thirty patients underwent dynamic 60-min [(11)C]HED scans with online arterial blood sampling. Single-tissue and both reversible and irreversible two-tissue models were fitted to the data using the metabolite-corrected arterial input function. For each model, reliable fits were defined as those yielding outcome parameters with a coefficient of variation (CoV) <25%. The optimal model was determined using Akaike and Schwarz criteria and the F-test, together with the number of reliable fits. Simulations were performed to study accuracy and precision of each model. Finally, quantitative results obtained using a population-averaged metabolite correction were evaluated, and simplified retention index (RI) and standardized uptake value (SUV) results were compared with quantitative volume of distribution (V T) data. RESULTS The reversible two-tissue model was preferred in 75.8% of all segments, based on the Akaike information criterion. However, V T derived using the single-tissue model correlated highly with that of the two-tissue model (r (2) = 0.94, intraclass correlation coefficient (ICC) = 0.96) and showed higher precision (CoV of 24.6% and 89.2% for single- and two-tissue models, respectively, at 20% noise). In addition, the single-tissue model yielded reliable fits in 94.6% of all segments as compared with 77.1% for the reversible two-tissue model. A population-averaged metabolite correction could not be used in approximately 20% of the patients because of large biases in V T. RI and SUV can provide misleading results because of non-linear relationships with V T. CONCLUSIONS Although the reversible two-tissue model provided the best fits, the single-tissue model was more robust and results obtained were similar. Therefore, the single-tissue model was preferred. RI showed a non-linear correlation with V T, and therefore, care has to be taken when using RI as a quantitative measure.
منابع مشابه
Correlation between scintigraphic evidence of regional sympathetic neuronal dysfunction and ventricular refractoriness in the human heart.
BACKGROUND Denervation supersensitivity has been proposed as a mechanism for the relation between ventricular arrhythmias and the sympathetic nervous system. Evaluation of this phenomenon in humans has become feasible only recently with the development of noninvasive scintigraphic methods for evaluating the pattern of sympathetic innervation. The purpose of this study was to determine if scinti...
متن کاملImpaired Myocardial Sympathetic Innervation Is Associated with Diastolic Dysfunction in Heart Failure with Preserved Ejection Fraction: 11C-Hydroxyephedrine PET Study.
Diastolic dysfunction is important in the pathophysiology of heart failure with preserved ejection fraction (HFpEF). Sympathetic nervous hyperactivity may contribute to the development of diastolic dysfunction. The aim of this study was to determine the relationship between myocardial sympathetic innervation quantified by 11C-hydroxyephedrine PET and diastolic dysfunction in HFpEF patients. Met...
متن کاملQuantification of [C]-meta-hydroxyephedrine uptake in human myocardium
Background: The aims of this study were to determine the optimal tracer kinetic model for [C]-meta-hydroxyephedrine ([C]HED) and to evaluate the performance of several simplified methods. Methods: Thirty patients underwent dynamic 60-min [C]HED scans with online arterial blood sampling. Single-tissue and both reversible and irreversible two-tissue models were fitted to the data using the metabo...
متن کاملWhole-body PET/CT with 11C-meta-hydroxyephedrine in tumors of the sympathetic nervous system: feasibility study and comparison with 123I-MIBG SPECT/CT.
UNLABELLED The 11C-labeled tracer meta-hydroxyephedrine (11C-HED) is a noradrenaline analog that was developed to visualize the sympathetic nervous system with PET. Initial clinical studies show a rapid uptake of 11C-HED in localized tumors of this system. Whole-body imaging with 11C-HED PET is now possible as PET/CT scanners allow a rather short examination time. The aim of this study was to e...
متن کامل