The influence of a slow-release multi-trace element ruminal bolus on trace element status, number of ovarian follicles and pregnancy outcomes in synchronized Afshari ewes.

نویسندگان

  • E Abdollahi
  • H Kohram
  • M H Shahir
  • M H Nemati
چکیده

Published data on the effects of ruminal bolus on the number of ovulatory follicles in ewes does not exist. The present study determined the effects of a ruminal bolus on trace element status, follicular dynamics and reproductive performance in ewes. Eighty Afshari cycling ewes were synchronized during breeding season using CIDR for 14 days and assigned to 4 groups (n=20); group 1 received a single Ferrobloc bolus four weeks prior to CIDR insertion following 400 IU eCG on CIDR removal, group 2 received two boluses four weeks prior to CIDR insertion following 400 IU eCG on CIDR removal, group 3 received only 400 IU eCG on CIDR removal and group 4 (control) received no bolus and no eCG. Transrectal ultrasonography was done to monitor the ovarian follicles on the day of CIDR removal and a day later. Results showed that boluses increased the status of copper, selenium and iodine on mating day and days 90 to 100 of gestation. Ruminal bolus did not significantly increase the number of different classes of ovarian follicles in ewes fed a diet meeting all trace mineral requirements. All ewes eventually became pregnant with 1 or 2 boluses but the multiple births rate (80%) was higher (P<0.05) after 2 boluses compared to the other groups.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The influence of a slow-release multi-trace element ruminal bolus on trace element status, number of ovarian follicles and pregnancy outcomes in synchronized Afshari ewes

Published data on the effects of ruminal bolus on the number of ovulatory follicles in ewes does not exist. The present study determined the effects of a ruminal bolus on trace element status, follicular dynamics and reproductive performance in ewes. Eighty Afshari cycling ewes were synchronized during breeding season using CIDR for 14 days and assigned to 4 groups (n=20); group 1 received a si...

متن کامل

Enhanced reproductive performance of ewes given a sustained-release multi-trace element/vitamin ruminal bolus.

A sustained-release multi-trace element/vitamin bolus has been devised for administration to ewes in advance of mating. Each bolus contained 5.3g Cu, 50mg Se, 90mg Co, 100mg I, 3.2g Mn and 4.7g Zn with 268x10(3) IU Vitamin A, 54x10(3) IU Vitamin D and 800 IU Vitamin E. About 50% of each nutrient is released during the first 6 weeks. Thereafter the release rate slows and over the remaining life ...

متن کامل

Control of Haemonchus contortus in goats with a sustained-release multi-trace element/vitamin ruminal bolus containing copper.

The objective of this study was to determine the effectiveness of a sustained-release multi-trace element/vitamin ruminal bolus (TEB) containing copper administered to mature does for control of gastrointestinal nematodes (GIN) during summer months and during late gestation. Haemonchus contortus was the predominant nematode during these trials. In Experiment 1, yearling Spanish does were untrea...

متن کامل

Performance, Health Status, and Colostrum Yield of Twin-Bearing Afshari Ewes as Well as Growth and Survival of Their Offspring are not Affected by Increasing Dietary Metabolizable Protein in Late Pregnancy

The aim of this study was to investigate the effects of two dietary metabolizable protein (MP) concentrations on the performance and health status of Afshari ewes and survival and growth of their lambs during late pregnancy. For 6 weeks prior to lambing, 32 Afshari ewes were randomly assigned to two dietary treatments, containing low (LMP) or high (HMP) MP concentrations. The ewes in LMP (n=16)...

متن کامل

Elimination of Chemical and Spectral Interferences in Measurement of Trace Elements in Urine and Blood by Combined Electrodeposition-Electrothermal Atomic Absorption Spectrometry

A combined electrodeposition-ETAAS technique has been applied to the analysis of Pb, Cd, Co, Ni, Cr and Mn in biological samples in order to overcome interferences and to minimize sample pretreatment. It requires minimal sample preparation with the electrolysis process aiding partial decomposition of the organic matrix, adequate for the release and deposition of trace elements. In an initia...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Iranian journal of veterinary research

دوره 16 1  شماره 

صفحات  -

تاریخ انتشار 2015