The effect of gender and respirator brand on the association of respirator fit with facial dimensions.

نویسندگان

  • R Kent Oestenstad
  • Leshan J Elliott
  • T Mark Beasley
چکیده

This study examined the association of facial dimensions with respirator fit considering the effect of gender and respirator brand. Forty-one subjects (20 white females and 21 white males) participated in the study. Each subject was measured for 12 facial dimensions using anthropometric sliding and spreading calipers and a steel measuring tape. Three quantitative fit tests were conducted with the same subject wearing one size of three different brands of half-mask respirators resulting in a total of nine fit tests. Linear mixed model analysis was used to model respirator fit as a function of gender and respirator brand while controlling for facial dimensions. Results indicated that the gender by respirator brand interaction was not statistically significant (p = 0.794), and there was no significant difference in respirator fit between males and females (p = 0.356). There was a significant difference in respirator fit among respirator brands (p < 0.001). Because correlations between facial dimensions and respirator fit differed across gender and respirator brand, six separate linear mixed models were fit to assess which facial dimensions most strongly relate to respirator fit using a "one variable at a step" backward elimination procedure. None of the 12 facial dimensions were significantly associated with respirator fit in all six models. However, bigonial breadth and menton-nasion length were significantly associated with respirator fit in five of the six models, and biectoorbitale breadth, bizygomatic breadth, and lip width were significantly associated with respirator fit in four of the six models. Although this study resulted in significant findings related to the correlation of respirator fit with menton-nasion length and lip width (the dimensions currently used to define the half-mask respirator test panel), other facial dimensions were also shown to be significantly associated with respirator fit. Based on these findings and findings from previous studies, it is suggested that other facial dimensions including bigonial breadth, biectoorbitale breadth, and bizygomatic breadth be considered when designing half-mask respirators, and that face length and lip width alone may not be appropriate in defining test groups whose fit is intended to be representative of worker populations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of half-face respirator fit in an Iranian petrochemical company's workers

Introduction: The performance of respirator-face piece is depending on a good contact between the worker's face and the respirator. Improper sealing can cause reduction in performance of respirators to protect health and safety of workers against risks related to chemical agents at work. This study is aimed to evaluate the fitness of half-face respirators and other related factors on it in an...

متن کامل

Factors affecting the location and shape of face seal leak sites on half-mask respirators.

While there have been a number of studies on the effect of leak site and shape on the magnitude of measured leakage through respirator face seals, there have been very few studies to identify the location and size of these leaks. In a previous study we used a method of identifying the location and shape of respirator leaks on a half-mask respirator by the deposition of a fluorescent tracer duri...

متن کامل

Facial anthropometric dimensions of Koreans and their associations with fit of quarter-mask respirators.

Past studies on respirator fit or performance have mostly been done for Whites or male subjects, and little attention has been paid to minorities and Asians. To fill this gap, this study was designed to provide facial anthropometric data for Koreans and to analyze the association between facial dimensions and respirator fit factors for three brands of quarter-mask respirators, two domestic and ...

متن کامل

Respirator fit of a medium mask on a group of South Africans: a cross-sectional study

BACKGROUND In South Africa, respiratory protective equipment is often the primary control method used to protect workers. This preliminary study investigated how well a common disposable P2 respirator fitted persons with a range of facial dimensions. METHODS Quantitative respirator fit tests were performed on 29 volunteers from different racial, gender and face size groups. Two facial dimensi...

متن کامل

New respirator fit test panels representing the current Chinese civilian workers.

Respirator fit test panels provide an objective tool for selecting representative human test subjects based upon their facial characteristics for use in research, product development, testing and certification. Fit test panels were typically based upon anthropometric data such as the 1967-1968 survey of American military personnel. In this study, the objectives were to: (i) evaluate the applica...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of occupational and environmental hygiene

دوره 4 12  شماره 

صفحات  -

تاریخ انتشار 2007