Diagnostic significance of prostate-specific antigen velocity at intermediate PSA serum levels in relation to the standard deviation of different test systems.

نویسندگان

  • A Manseck
  • C Pilarsky
  • S Froschermaier
  • M Menschikowski
  • M P Wirth
چکیده

Serial prostate-specific antigen (PSA) measurements (PSA velocity) as an additional instrument to detect prostatic cancer was introduced in 1992. It has previously been reported that PSA increase per year differed in the last 5 years prior to diagnosis in patients with benign prostatic hyperplasia (0.18 ng/ml/year), locally confined (0.75 ng/ml/year) and metastasized (4.4 ng/ml/year) cancer of the prostate (CaP) in contrast to healthy men (0.04 ng/ml/year). The ability of PSA velocity to detect organ-confined CaP in patients with intermediate PSA serum values depends therefore on a reliable and reproducible PSA result. The present study comprised 85 men with PSA values between 3 and 8 ng/ml (Abbott IMx). PSA measurements were repeated with Abbott IMx (n = 85 patients) and Hybritech Tandem-E (n = 59 patients) assays. The PSA serum values differed from one examination to the other from 0.02 to 2.74 ng/ml with the Abbott IMx. Standard deviation amounted to 0.35 ng/ml with the Abbott IMx PSA assay. Using the Hybritech Tandem-E assay, mean standard deviation was 1.15 ng/ml and therefore higher than with the Abbott IMx assay. The difference from one test to the other ranged from 0.05 to 4.05 ng/ml with the Hybritech Tandem-E. Using the Abbott IMx assay, 10.6% of all repeat measurements exceeded 1 ng/ml whereas in the Hybritech Tandem-E assay 62.7% of the second measurements differed > 1 ng/ml from the first PSA result. An increase in PSA serum values may therefore be due to intratest variation, physiological day-to-day variation as well as prostatic disease. It is important to notice that the intra-assay variation may be greater than the PSA increase per year in a patient with CaP. Therefore, PSA velocity seems to be of limited value.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

What is the most appropriate test in detecting prostate cancer in patients with intermediate prostate specific antigen levels?

  Abstract   Background: Regarding the variety of tests present for detecting and also screening   prostate cancer and also bearing in mind the advantages and disadvantages of   these tests we decided to re-evaluate these tests (total prostate specific antigen and all   of its modifications) in detecting prostate cancer in men with intermediate serum   PSAlevels.   Methods: Following a cross se...

متن کامل

Age Specific Reference Levels of Serum Prostate-Specific Antigen, Prostate Volume and Prostate Specific Antigen Density in Healthy Iranian Men

Background: It is relevant to highlight that there is not a precise and perfect report on either 95 percentile value (upper limit of normal range) or on appropriate reference intervals for serum PSA in Iranian population. Objective: To determine age-specific reference ranges for serum prostate-specific antigen (PSA) concentration and PSA density (PSAD) and prostate volumes in a population of he...

متن کامل

Preparation of an artificial matrix to replace human standards of prostate specific antigen IRMA assay kit [Persian]

  Introduction: Prostate specific antigen (PSA) is one of the most sensitive markers for diagnosis of prostate cancer. Immunoradiometric kit (IRMA) is a common and sensitive method for determination of PSA in clinical laboratories. This kit has four major components: solid phase coated with monocolonal antibody, pair antibody labelled with I-125, series of standards i...

متن کامل

Prostate specific antigen staining intensity in prostatic adenocarcinoma correlates with serum prostate specific antigen , Bandar Abbas, Iran

Introduction: Prostatic adenocarcinoma is one the most common malignances and the second cause of death in males due to cancer. Prostate Specific Antigen (PZSA) serum level is the first marker to screen such patients. We aimed in this study, to assess the intensity of prostatic adenocarcinoma tissue staining with PSA staining method. Methods: In this corss-sectional study, prostatic adenocarcin...

متن کامل

محدوده مرجع ویژه سن برای آنتی‌ژن سرمی اختصاصی پروستات (PSA) در مردان ایرانی

Background: Prostate-Specific Antigen (PSA), also known as gamma-seminoprotein or kallikrein-3 (KLK3), is the best marker for early diagnosis of prostate cancer. Since age and race are affecting PSA levels, determining age-specific reference ranges of PSA in every community is necessary for increasing the efficiency rate of PSA. The aim of the present study was to evaluate the normal distributi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Urologia internationalis

دوره 60 1  شماره 

صفحات  -

تاریخ انتشار 1998