Design and performance of the UCLH mark 1b 64 channel electrical impedance tomography (EIT) system, optimized for imaging brain function.

نویسندگان

  • R J Yerworth
  • R H Bayford
  • G Cusick
  • M Conway
  • D S Holder
چکیده

The UCLH Mark 1b is a portable EIT system that can address up to 64 electrodes, which has been designed for imaging brain function with scalp electrodes. It employs a single impedance-measuring circuit and multiplexer so that electrode combinations may be addressed flexibly using software. It operates in the relatively low frequency band between 225 Hz and 77 kHz, as lower frequencies produce larger changes during brain activity, and has a videocassette-sized headbox on a lead 10 m long, connected to a base box the size of a video recorder, and notebook PC, so that recordings may be made in ambulant subjects. Its performance was assessed using a resistor-capacitor network, and two saline-filled tanks-a cylindrical Perspex one and a latex one which contained a human skull. System signal-to-noise ratio was better than 50 dB and the maximum reciprocity error less than 10% for most frequencies. The CMMR was better than 80 dB at 38 kHz and a sponge, 20 mm across, which caused a local 12% impedance increase, was correctly localized in images. This suggests that the system has adequate performance to image impedance changes of 5-50% known to occur in the brain during normal activity, epilepsy or stroke; clinical trials to image these conditions are in progress.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrical impedance tomography spectroscopy (EITS) for human head imaging.

Electrical impedance tomography (EIT) is a recently developed medical imaging method which has practical advantages for imaging brain function as it is inexpensive, rapid and portable. Its principal use in validated human studies to date has been to image changes in impedance at a single excitation frequency over time, but there are potential applications where it is desirable to obtain images ...

متن کامل

Applications of Electrical Impedance Tomography in Neurology

Introduction: Electrical impedance tomography (EIT) is a non-invasive technique utilized in various medical applications, including brain imaging and other neurological diseases. Recognizing the physiological and anatomical characteristics of organs based on their electrical properties is one of the main applications of EIT, as each variety of tissue structure has its own electrical characteris...

متن کامل

Evaluation of the use of gold nanoparticle as contrast agent in electrical impedance imaging

Introduction: Electrical Impedance Tomography (EIT) is a real time and minimal invasive imaging modality for detection of lesions in tissues even when their structures show no changes. Early detection of lesion with EIT depends on difference between electrical impedance of targeted tissue and its surroundings. Therefore, finding a contrast agent for EIT that increase this diffe...

متن کامل

The Effect of Gold Nanoparticle on Electrical Impedance of Tissue on Low Frequency Ranges

Introduction: Electrical impedance of tissues on low frequencies includes useful information about functional and structural changes in tissues. This property is used in Electrical Impedance Tomography (EIT) imaging modality for the detection of lesions in tissues.Objective: The goal of this article is to study changes in electrical impedance of tissues in the presence of gold nanoparticles.Mat...

متن کامل

Multi-frequency electrical impedance tomography (EIT) of the adult human head: initial findings in brain tumours, arteriovenous malformations and chronic stroke, development of an analysis method and calibration.

MFEIT (multi-frequency electrical impedance tomography) could distinguish between ischaemic and haemorrhagic stroke and permit the urgent use of thrombolytic drugs in patients with ischaemic stroke. The purpose of this study was to characterize the UCLH Mk 2 MFEIT system, designed for this purpose, with 32 electrodes and a multiplexed 2 kHz to 1.6 MHz single impedance measuring circuit. Data we...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physiological measurement

دوره 23 1  شماره 

صفحات  -

تاریخ انتشار 2002