Polymethylmethacrylate (PMMA) as an embedding medium preserving tissues and foreign materials encroaching in endovascular devices.

نویسندگان

  • R Guidoin
  • Z Zhang
  • Y Douville
  • M-F Baslé
  • F Grizon
  • G R Marinov
  • C K Zarins
  • A P Legrand
  • R Guzman
چکیده

Problems of displacement, poor healing, degradation of the polymers and corrosion of the metallic frame in endovascular devices still require in-depth investigations. As the tissues and the foreign materials are in close contact, it is of paramount importance to efficiently investigate the interfaces between them. Inclusion in polymethymethacrylate (PMMA) permits us to obtain thin slides and preserve the capacity to perform the appropriate stainings. An AneuRx prosthesis was harvested in bloc with the surrounding tissues at the autopsy of a patient 25 months post deployment in a 5.7 cm diameter AAA and sectioned in the direction of the blood flow in two halves. A cross-section of the encapsulated distal segment together with the surrounding aneuryshmal sac was embedded in polymethylmethacrylate (PMMA). Further to complete polymerization, slices of the specimen were cut on a precision banding saw under coolant. They were affixed onto methacrylate slides with a UV cured adhesive. Binding and polishing were done on a numeric grinder and slices 25 to 30 microm in thickness were stained with toluidine blue prior to observation in light microscopy. Additional slices were prepared for scanning electron microscopy and X-ray energy dispersive spectrometry for determination of the elemental composition of the Nitinol stent. The aortic wall did not demonstrate complete integrity along with its circumference. Some areas of rupture were noted. The content of the sac was heavily shrunk and was mostly acellular. The walls of the device were very well encapsulated. The PMMA embedding permitted the polyester wall, the Nitinol wire and the collagen to keep in close contact. Scanning electron microscopy involved backscattered electrons and confirmed the corrosion the Nitinol wire at the boundary with living tissues. Based upon the results obtained, we believe that PMMA embedding is the most appropriate method to process endovascular devices for histological and material investigation. Needless to say, that paraffin embedding would have not been feasible for such a big size specimen involving different materials.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

MRI virtual biopsies: analysis of an explanted endovascular device and perspectives for the future.

Information that can be obtained by magnetic resonance imaging (MRI) of explanted endovascular devices must be validated as this method is non-destructive. Histology of such a device together with its encroached tissues can be elegantly performed after polymethymethacrylate (PMMA) embedding, but this approach requires destruction of the specimen. The issue is therefore to determine if the MRI i...

متن کامل

Foreign body granuloma after bone cement augmentation of pedicle screws for osteoporotic spinal surgery: A case report

Osteoporosis causes a decrease in bone mineral density. To overcome the decrease in fixation strength, a variety of techniques and devices have been developed, including cement augmentation of pedicle screws. Polymethyl methacrylate (PMMA), is commonly known as bone cement, and is widely used for implant fixation in various orthopaedic and spine surgery. In general, PMMA augmentation of pedicle...

متن کامل

Epithelialization Over a Scaffold of Antibiotic-Impregnated PMMA Beads: A Salvage Technique for Open Tibial Fractures with Bone and Soft Tissue Loss When all Else Fails

  The management of soft tissue defects in tibial fractures is essential for limb preservation. Current techniques are not without complications and may lead to poor functional outcomes. A salvage method is described using three illustrative cases whereby a combination of flaps and antibiotic-impregnated polymethylmethacrylate beads are employed to fill the bony defect, fight the infection, and...

متن کامل

Polymethylmethacrylate/Silver Nanocomposite Prepared by γ-Ray

Polymethylmethacrylate-silver (PMMA/Ag) nanocomposite is synthesized by irradiating the solution of silver ions in methylmethacrylate monomer by γ-ray. In this method, polymerization of the methylmethacrylate monomer and the silver ion reduction occurred simultaneously. Optical properties of the PMMA/Ag solutions are investigated using UV-Vis spectroscopy. The structural characterizations of th...

متن کامل

Flow Visualization in Artificial Porous Media from Microfluidic PMMA Devices

Microfluidic polymethylmethacrylate (PMMA) devices for study of particle transport in artificial porous media were designed and microfabricated using hot embossing with a brass mold insert containing a microchannel network with eight layers. After thermal bonding to enclose the microchannel network, a process protocol was applied to successfully remove bubbles in the PMMA device. Characterizati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Artificial cells, blood substitutes, and immobilization biotechnology

دوره 34 3  شماره 

صفحات  -

تاریخ انتشار 2006