Unusual neutral pH assisted electrochemical polymerization of aniline on a MWCNT modified electrode and its enhanced electro-analytical features.

نویسندگان

  • Nandimalla Vishnu
  • Annamalai Senthil Kumar
  • K Chandrasekara Pillai
چکیده

Unusual electropolymerization of aniline to polyaniline (PANI) in a neutral pH solution has been successfully demonstrated using a multiwalled carbon nanotube (MWCNT) modified gold electrode (Au-MWCNT@PANIpH7). The modified electrode showed highly redox active surface confined peaks corresponding to the molecular transitions of leucoemeraldine-emeraldine and emeraldine-pernigraniline in pH 7 phosphate buffered solution (PBS), along with a low capacitance behavior, in contrast to the conventional acidic solution PANI systems. Control experiments in the absence of MWCNTs (i.e., Au/PANIpH7) and in an acidic medium, pH 2 (i.e., Au-MWCNT@PANIpH2), resulted in nil and poor redox features respectively. The physicochemical characterization of the MWCNT@PANIpH7 film by TEM, Raman spectroscopy, FTIR and UV-Vis revealed the presence of polaron type PANI structures on the MWCNT surface. More interestingly, MWCNT@PANIpH7 showed a highly selective electrocatalytic signal to ascorbic acid (AA) at a low oxidation potential, -15 mV vs. Ag/AgCl, without interference from nitrite, uric acid, dopamine, glucose, cysteine and citric acid in pH 7 PBS. Extended flow injection analysis yielded an excellent AA sensing response with a detection limit (signal-to-noise ratio = 3) of 42 nM, which is better than that of the conventional acid assisted MWCNT@PANIpH2 and MWCNT systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Direct DNA Immobilization onto a Carbon Nanotube Modified Electrode: Study on the Influence of pH and Ionic Strength

Over the past years, DNA biosensors have been developed to analyze DNA interaction and damage that have important applications in biotechnological researches. The immobilization of DNA onto a substrate is one key step for construction of DNA electrochemical biosensors. In this report, a direct approach has been described for immobilization of single strand DNA onto carboxylic acid-functionalize...

متن کامل

Electrochemical Behavior of 2-Aminothiazole at Poly Glycine Modified Pencil Graphite Electrode

Electro analysis of 2-Aminothiazole (2-AT) by a low cost poly Glycine modified Pencil Graphite Electrode (poly Gly/PGE) was studied using of cyclic voltammetric (CV) and differential pulse voltammetric (DPV) techniques. The optimal experimental conditions to determine 2-AT was setup by the variation of the current with scan rate, concentration and pH. Electrochemical performance of the 2-AT at ...

متن کامل

Determination of Acetaminophen Via TiO2/MWCNT Modified Electrode

Electrochemical behaviour of acetaminophen at the multi wall carbon nanotubes/titanium dioxide (MWCNT/TiO2) composite film modified glassy carbon electrode (GCE) via solvent casting method was studied. It is shown that the MWCNT/TiO2/GCE exhibits remarkable improvement in analytical response as compared to other electrodes. Comparing the responses of the MWCNT/TiO2/GCE with that obtained at the...

متن کامل

Electrochemical Sensor for Determination of Fenitrothion at Multi-wall Carbon Nanotubes Modified Glassy Carbon Electrode

A sensor, based on multi-wall carbon nanotubes modified glassy carbon electrode (MWCNT/GCE), was developed for determination of fenitrothion. Determining the surface area of MWCNT/GCE showed that this surface is three times more active than that of a glassy carbon electrode. The experimental parameters, such as the amount of MWCNTs, pH of the fenitrothion solution, preconcentration potential an...

متن کامل

Highly improved methanol oxidation onto carbon paste electrode modified by nickel particles dispersed into poly (2,5-dimethylaniline) film

In this work, modification of carbon paste electrode surface with poly (2, 5-Dimethyl aniline) (P-2,5-DMA) by using electrochemical polymerization was described. Then, transition metal ions of Ni(II) were incorporated into the polymer film by two ways. At first way, the polymeric modified electrode was immersed in 0.2 M NiSO4 solutions and the second way was carried out by electrodeposition of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 138 21  شماره 

صفحات  -

تاریخ انتشار 2013