The efficacy of sonographic measurement of inferior vena cava diameter as an estimate of central venous pressure

نویسندگان

  • William Ciozda
  • Ilan Kedan
  • Devin W. Kehl
  • Raymond Zimmer
  • Raj Khandwalla
  • Asher Kimchi
چکیده

BACKGROUND Central venous pressure (CVP) and right atrial pressure (RAP) are important parameters in the complete hemodynamic assessment of a patient. Sonographic measurement of the inferior vena cava (IVC) diameter is a non-invasive method of estimating these parameters, but there are limited data summarizing its diagnostic accuracy across multiple studies. We performed a comprehensive review of the existing literature to examine the diagnostic accuracy and clinical utility of sonographic measurement of IVC diameter as a method for assessing CVP and RAP. METHODS We performed a systematic search using PubMed of clinical studies comparing sonographic evaluation of IVC diameter and collapsibility against gold standard measurements of CVP and RAP. We included clinical studies that were performed in adults, used current imaging techniques, and were published in English. RESULTS Twenty one clinical studies were identified that compared sonographic assessment of IVC diameter with CVP and RAP and met all inclusion criteria. Despite substantial heterogeneity in measurement techniques and patient populations, most studies demonstrated moderate strength correlations between measurements of IVC diameter and collapsibility and CVP or RAP, but more favorable diagnostic accuracy using pre-specified cut points. Findings were inconsistent among mechanically ventilated patients, except in the absence of positive end-expiratory pressure. CONCLUSION Sonographic measurement of IVC diameter and collapsibility is a valid method of estimating CVP and RAP. Given the ease, safety, and availability of this non-invasive technique, broader adoption and application of this method in clinical settings is warranted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The efficacy of inferior vena cava diameters and the jugular vein in assessing fluid resuscitation

Objective: Fluid resuscitation is necessary in almost all critical patients. The central venous pressure (CVP) is a well-established method of assessing resuscitation. Recently, there have been attempts to investigate less invasive methods like the diameters of inferior vena cava (IVC) or the jugular vein. We aimed to investigate this method in our research.Methods: Seventy eight critical...

متن کامل

Correlation of Ultrasonographic Measurement of Inferior Vena Cava Collapsibility Index with Central Venous Pressure in Diagnosis and Management of Neonatal Shock

Background: Neonatal intensive care unit (NICU)Conventionally, Central Venous Pressure (CVP) monitoring has beenused by intensivists to measure intravascular volume. However, it is an invasive procedure resulting in many complications. Non-invasive ultrasonographic measurement of inferior vena cava collapsibility index (IVC-CI) is a promising alternative. Therefore, this study wasconducte...

متن کامل

Correlation between Central Venous Pressure and Inferior Vena Cava Sonographic Diameter; Determining the Best Anatomic Location

INTRODUCTION The correlation of central venous pressure (CVP) with inferior vena cava (IVC) sonographic diameter has been reported in several studies. However, few studies have attempted to find the best anatomic location of measurement. Therefore, the purpose of this study was determining the best anatomic location to find precise correlation between CVP and IVC diameter using transesophageal ...

متن کامل

بررسی ارزش تشخیصی میزانCaval index در تعیین فشار ورید مرکزی پایین در مقایسه با روش تهاجمی در بیماران بستری در ICU بیمارستان شهید باهنر کرمان

Introduction: Measurement of central venous pressure can be regarded as a beneficial guide in order to assess a patient's hemodynamic status, specifically in patient with sever sepsis and septic shock, for whom a central venous pressure of less than 8mmhg is considered as an indicator for aggressive intravenous fluid replacement. Therefore, this study aimed to investigate the ultrasonographic e...

متن کامل

Internal Jugular Vein Height and Inferior Vena Cava Diameter Measurement using Ultrasound to Determine Central Venous Pressure: A Correlation Study.

OBJECTIVE To determine the correlation between central venous pressure (CVP) measured by conventional central venous access and ultrasonographic measurement of internal jugular vein (IJV) height and inferior vena cava (IVC) diameter. METHODS A prospective, cross-sectional, convenience sampling observational study. RESULTS 25 patients from the Emergency Department (ED) Universiti Kebangsaan ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2015