Cotton induced bronchoconstriction detected by a forced random noise oscillator.
نویسندگان
چکیده
Lung function responses to inhaled cotton dust were evaluated in a group of 58 healthy subjects by spirometry (MEFV curves) and forced random noise impedance parameters. Twenty-one of these subjects were also examined by body plethysmography to assess changes in airway resistance (Raw). For the study group as a whole, alterations in lung mechanical function after exposure to cotton dust were detected by maximal expiratory volumes and flows (p less than 0.001) and impedance parameters (p less than 0.01) but not by Raw. Subjects showing responses in MEFV curves also showed increases in Thevenin or effective resistance at low frequencies (R1, R5-9, R5-9/R20-24), suggesting that the limitation of flow occurred predominantly in the peripheral airways. By contrast, non-responders on MEFV measurements were found to have significant increases in effective resistance both at low and at high frequencies (R1, R5-9, R20-24), suggesting a central airways effect. MEFV curve non-responders also exhibited a significantly lower baseline effective resistance profile than MEFV curve responders. The data indicate that under the conditions of the experiment measures of the Thevenin resistance (real part of impedence) by the forced random noise method are reliable indicators of cotton induced bronchoconstriction. Measurement variability, however, suggests that, at present, these are more appropriate for group studies and should remain adjuncts to standard tests of lung function such as spirometry.
منابع مشابه
Attractors of a randomly forced electronic
This paper examines an electronic oscillator forced by a pseudo-random noise signal. We give evidence of the existence of one or more random at-tractors for the system depending on noise amplitude and system parameters. These random attractors may appear to be random xed points or random chaotic attractors. In the latter case, we observe a form of intermittent synchronization of the response of...
متن کاملHuman ventilatory response to washed and unwashed cottons from different growing areas.
Thirty volunteer subjects were exposed to controlled amounts of respirable dust generated by the carding of cotton in an experimental cardroom. Eighteen exposures each lasting six hours were performed while carding unwashed and washed cottons from the three major growing regions of the United States. Elutriated dust was analysed gravimetrically and was comparable (0.59 mg/m3 +/- 0.04) for all e...
متن کاملA Phase Noise Reduction Technique in LC Cross-coupled Oscillators with Adjusting Transistors Operating Regions
In this paper, an intuitive analysis of a phase noise reduction technique is done, and then a modified structure is proposed to achieve higher phase noise reduction than the original one. This method reduces the impact of noise sources on the phase noise by decreasing closed-loop gain in zero-crossings points and moving this high closed-loop gain to the non-zero-crossings points. This reduction...
متن کاملCOMPARING NUMERICAL METHODS FOR THE SOLUTION OF THE DAMPED FORCED OSCILLATOR PROBLEM
In this paper, we present a comparative study between the Adomian decomposition method and two classical well-known Runge-Kutta and central difference methods for the solution of damped forced oscillator problem. We show that the Adomian decomposition method for this problem gives more accurate approximations relative to other numerical methods and is easier to apply.
متن کاملAdenosine level in exhaled breath increases during exercise-induced bronchoconstriction.
In asthmatic patients, airway obstruction provoked by exercise challenge is accompanied by an increase in plasma adenosine level. In this study, the current authors investigated if exercise-induced bronchoconstriction was associated with local changes of adenosine concentration in the airways. Oral exhaled breath condensate (EBC) collection (5-min duration) and forced expiratory volume in one s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of industrial medicine
دوره 41 4 شماره
صفحات -
تاریخ انتشار 1984