Partial Discharge Location within a Transformer Winding Using Principal Component Analysis
نویسندگان
چکیده
Partial discharge (PD) may occur in a transformer winding due to ageing processes, operational over stressing or defects introduced during manufacture. The presence of PD does not necessarily indicate imminent failure of the transformer but it will lead to serious degradation and ageing mechanisms which can be considered as a precursor of transformer failure. A necessary step is required in order to prevent degradation due to PD activity which may ultimately lead to failure. PD might occur anywhere along the transformer winding, the discharge signal can propagate along the winding to the bushing and neutral to earth connections. As far as maintenance and replacement processes are concerned, it is important to identify the location of PD activity so any repair or replace decision is assured to be cost effective. Therefore, identification of a PD source as well as its location along the transformer winding is of great interest to both manufacturers and system operators. The proposed method for locating PD sources in windings is based on wavelet filtering and principal component analysis. An experiment has been developed based on a high voltage winding section that has been used to produce PD measurement data and to investigate the feasibility of the proposed approach.
منابع مشابه
Pattern Classification of Partial Discharge in Lv Winding of 1- Transformer Using Pca
Partial discharge is the commencement of failure of insulation of electrical devices used at high voltage. If such discharge is not detected then fault may increase at the working duration. Basically partial discharge is the cause of failure of insulation in electrical equipment. The insulation of electrical equipment deteriorates due to thermal, mechanical, electrical and environmental stresse...
متن کاملEvaluating the Improvement of Partial Discharge Localization Accuracy Using Frequency Response Assurance Criterion
Partial Discharge (PD) is the most important source of insulation degradation in power transformers. In order to prevent catastrophic failures in transformers, PDs need to be located as soon as possible so that maintenance measures can be taken in time. Due to the structural complexity of windings, locating the PD source inside a transformer winding is not a simple task. In this paper, the effi...
متن کاملLumped Parameter Model for High Frequency Partial Discharge Estimation in High Voltage Transformer
Lumped Parameter Model is well known in solving high frequency signal propagation in high voltage transformer windings. At Southampton University, the modelling technique has been improvised and employed to solve partial discharge (PD) problem occurred within deep inside transformer windings. Firstly, a lumped capacitive parameter model was considered and secondly a transmission line lumped par...
متن کاملInvestigation of Partial Discharge Propagation and Location in Multiple-α and Single- Α Transformer Windings Using Optimized Wavelet Analysis
Partial discharges (PD) are recognized as the main cause of the inner insulation deterioration process in power transformers. Therefore, the optimum inner insulation design is one of the challenges a transformer designer is faced with. Transformer strength, especially during transient conditions, is a criterion for transformer insulation designers. This challenge has made designers initiate and...
متن کاملFuture template numerical interpretation techniques for PD pulse location in transformer windings
Identification and location of partial discharge (PD) source is an important diagnostic tool for reliable operation of transformer. In this paper, future template numerical interpretation techniques are proposed for location of PD pulse duration from 0.1 s to 5 s in transformer windings using sweep frequency response analysis (SFRA) principle. To analyze the efficacy of the proposed techniques ...