Quantifying the importance of the atmospheric sink for polychlorinated dioxins and furans relative to other global loss processes
نویسندگان
چکیده
[1] Previous attempts to establish global mass balances for polychlorinated dioxins and furans (PCDD/Fs) have focused on the terrestrial sink, thereby neglecting deposition to the oceans and atmospheric losses. In this study, the atmospheric sink of polychlorinated dioxins and furans (PCDD/Fs) was calculated on the basis of their presence in soils. OH radical ([OH]) depletion reactions compete with atmospheric deposition fluxes for the fate of atmospheric PCDD/Fs. Three different steady state scenarios were considered: scenario A was a one-box atmosphere with globally averaged [OH], temperature (T), atmospheric lifetime (tlife), and a constant gas-particle partitioning (F); in scenario B, [OH], T, and F were averaged in a multibox atmosphere, with a constant tlife; and in scenario C, tlife was varied. In scenario A the strength of the atmospheric sink was 2400–2800 kg/yr; in scenario B it was 2100 kg/yr; in scenario C, it was 1,800 kg/yr (tlife = 5.4 days) to 2,800 kg/yr (tlife = 14 days). The majority of the atmospheric sink was due to the depletion of Cl4DFs (1300–1400 kg/yr), followed by Cl4DDs (360–380 kg/yr) and Cl5DFs (230–240 kg/yr). On a global scale, major sinks for PCDD/Fs are the deposition to terrestrial soils and the oceans. For Cl6–8DDs, deposition to soils outweighs depletion reactions in the atmosphere and ocean uptake. The more volatile Cl4–5DD/Fs, however, are true ‘‘multimedia’’ compounds, with their estimated atmospheric sink being roughly as important as the terrestrial sink (in the case of Cl5DD/Fs) or outweighing it (e.g., Cl4DD/Fs).
منابع مشابه
Oceanic biogeochemical controls on global dynamics of persistent organic pollutants.
Understanding and quantifying the global dynamics and sinks of persistent organic pollutants (POPs) is important to assess their environmental impact and fate. Air-surface exchange processes, where temperature plays a central role in controlling volatilization and deposition, are of key importance in controlling global POP dynamics. The present study is an assessment of the role of oceanic biog...
متن کاملAtlantic ocean surface waters buffer declining atmospheric concentrations of persistent organic pollutants.
Decreasing environmental concentrations of some persistent organic pollutants (POPs) have been observed at local or regional scales in continental areas after the implementation of international measures to curb primary emissions. A decline in primary atmospheric emissions can result in re-emissions of pollutants from the environmental capacitors (or secondary sources) such as soils and oceans....
متن کاملDioxins and furans in air and deposition: a review of levels, behaviour and processes.
This paper is a comprehensive, critical review of the levels, behaviour and processes affecting polychlorinated dibenzo-p-dioxins and -furans (PCDD/Fs) in air and deposition. Aspects of sampling, analysis and quality assurance/control are discussed initially, before a review of the PCDD/F concentrations in ambient air is presented. The general trend in sigma P4-8 CDD/F (and sigma TEQ) is: remot...
متن کاملPCB and PAH Releases from Incineration and Power Generation Processes
All rights reserved. No part of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording or otherwise without the prior permission of the Environment Agency. The views expressed in this document are not necessarily those of the Environment Agency. Its officers, servants or agents accept no liabili...
متن کاملOccupational exposure to polychlorinated dioxins, polychlorinated furans, polychlorinated biphenyls, and biphenylenes after an electrical panel and transformer accident in an office building in Binghamton, NY.
A polychlorinated biphenyl (PCB) and tri- and tetrachlorinated benzene-containing electrical transformer was involved in an explosion and fire in a modern office building in Binghamton, New York, on February 5, 1981. Because of an unusual system of air shafts the entire building and adjacent garage became contaminated with toxic chemicals. Polychlorinated dioxins, furans, and biphenylenes were ...
متن کامل