OPTIMISING THE START-UP OF A 10Hz BOOSTER POWER SUPPLY
نویسندگان
چکیده
The Synchrotron Radiation Source (SRS) at Daresbury Laboratory has a 600MeV Booster, fed by an energy storage power supply configuration (White Circuit). The design consists of two power supplies : an AC source to supply the losses to the parallel resonant circuits and a DC supply to fully bias the AC sinewave. In a recent modernisation of the control electronics, different methods of achieving reliable synchronisation of the AC source on switch-on have been investigated. The circuitry must deal with the high Q value of the resonant circuits and variation in resonant frequency with both ambient temperature and the applied DC current. This paper presents the different designs explored to improve the efficiency of start-up and discusses the problems encountered. The chosen design and test results are detailed with recommendations for future investigations.
منابع مشابه
منبع تغذیه مغناطیسهای حلقه افزاینده انرژی طرح چشمه نور ایران
The Iranian Light Source Facility (ILSF) booster main specifications including 250 ms ramp up, 2Hz repetition rate, and quasi-sinusoidal wave shape, up to this point have been the basis for calculations. Each family of magnets including Dipole, Quadrupole and Sextupoles will feed by individual power supply. In order to maintain constant transverse tunes and chromaticity while the beam is accele...
متن کاملThe required power of the MGT-40 gas turbine starter
Determination of the starter torque-speed diagram is a major task in the design or selection of a proper gas turbine starter. In this paper, the maximum power of the MGT-40 gas turbine starter was calculated based on the dynamics of the rotor, start-up logic, and compressor map. In a recent research, the pressure ratio was assumed as a linear function of the rotor speed and the required sta...
متن کاملThe required power of the MGT-40 gas turbine starter
Determination of the starter torque-speed diagram is a major task in the design or selection of a proper gas turbine starter. In this paper, the maximum power of the MGT-40 gas turbine starter was calculated based on the dynamics of the rotor, start-up logic, and compressor map. In a recent research, the pressure ratio was assumed as a linear function of the rotor speed and the required starter...
متن کاملDevelopment of CMOS imager block for capsule endoscope
This paper presents the development of imager block to be associated in a capsule endoscopy system. Since the capsule endoscope is used to diagnose gastrointestinal diseases, the imager block must be in small size which is comfortable for the patients to swallow. In this project, a small size 1.5V button battery is used as the power supply while the voltage supply requirements for other compone...
متن کاملThe Upgrade of Srrc Booster Extraction System
It is planned to upgrade the SRRC booster from 1.3 GeV to 1.5 GeV for full energy injection into the storage ring before the end of 1999. Based on the technical specification and operation experience, it is concluded that some of the subsystem components need to be rebuilt, such as the magnet power supply systems and beam extraction elements. A review of the power supply system will be reported...