Retrobulbar optic nerve diameter measured by high-speed magnetic resonance imaging as a biomarker for axonal loss in glaucomatous optic atrophy.

نویسندگان

  • Wolf A Lagrèze
  • Mirjam Gaggl
  • Matthias Weigel
  • Jürgen Schulte-Mönting
  • Anima Bühler
  • Michael Bach
  • Robin D Munk
  • Thorsten A Bley
چکیده

PURPOSE To assess a novel magnetic resonance imaging (MRI) protocol for quantifying the optic nerve diameter (OND) as a measure of axonal loss in the optic nerve. METHODS Included in the study was one eye each from 47 subjects, of whom 9 had no eye disease, 16 had preperimetric glaucoma, 11 had a glaucomatous mean visual field defect of <10 dB and 11 of >10 dB. Each subject underwent automated perimetry, scanning laser polarimetry, optic coherence tomography, scanning laser tomography, and ultrafast high-resolution MRI at 3 T. OND was determined 5, 10, and 15 mm behind the eye with a half Fourier-acquired single-shot turbo spin-echo (HASTE)-sequence requiring 1.5 seconds of data acquisition time per slice and providing a spatial resolution of 0.11 mm. A multiple linear regression model was applied to determine correlations (r) among the different techniques. RESULTS The correlation (r) was <0.37 for OND measurements taken 5 mm behind the eye. At 10 mm behind the eye, r increased to 0.57 and was statistically significant in four out six instances. In the orbital apex 15 mm behind the eye, r reached a maximum of 0.80 and was statistically significant in all instances. OND correlated best with the retinal nerve fiber layer thickness measured by optic coherence tomography. CONCLUSIONS Retina- or optic nerve head-related surrogate markers for axonal content correlated closely with the OND, although only when it was measured in the orbital apex. High-resolution MRI using an ultrafast HASTE-sequence at 3 T proved useful for OND quantification and may be a valuable asset in future neuroprotection trials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The correlation of changes of the optic nerve diameter in the acute retrobulbar neuritis with the brain changes in multiple sclerosis.

The aim of this paper is to compare diameter of healthy and affected optic nerve determined by ultrasound with brain lesions in acute retrobulbar neuritis in patients with multiple sclerosis. In this prospective study 20 patients with multiple sclerosis and acute retrobulbar neuritis were examined. Optic nerve diameter was measured by ultrasound. Brain lesions were detected by magnetic resonanc...

متن کامل

Demonstration of systematic variation in human intraorbital optic nerve size by quantitative magnetic resonance imaging and histology.

PURPOSE To use magnetic resonance imaging (MRI) to measure the diameter along the course of the intraorbital optic nerve in living subjects and cadaveric specimens, and to validate measurements histologically in the same specimens. METHODS Measurements of the intraorbital optic nerve were made in 23 living human subjects and in three formalin-fixed orbits using high-resolution, surface coil M...

متن کامل

Axonal loss from acute optic neuropathy documented by scanning laser polarimetry.

BACKGROUND/AIMS Retinal nerve fibre layer analysis by scanning laser polarimetry has been shown to facilitate diagnosis of glaucoma while its role in glaucoma follow up is still unclear. A major difficulty is the slow reduction of retinal nerve fibre layer thickness in glaucomatous optic neuropathy. Eyes of patients were studied after acute retrobulbar optic nerve lesion in order to evaluate th...

متن کامل

Letter to the Editor: A Case of Optic Nerve Atrophy with Severe Disc Cupping after Methanol Poisoning

We report a rare case of optic nerve atrophy with severe disc cupping resulting from methanol poisoning. A 30-year-old man presented to the hospital complaining of decreased visual acuity in both eyes a day after drinking alcohol containing methanol. His initial visual acuity allowed for only visualizing hand motion and not corrected in either eye. Initial intraocular pressure was within normal...

متن کامل

Magnetic resonance in studies of glaucoma

Glaucoma is the second leading cause of blindness. It affects retinal ganglion cells and the optic nerve. However, there is emerging evidence that glaucoma also affects other components of the visual pathway and visual cortex. There is a need to employ new methods of in vivo brain evaluation to characterize these changes. Magnetic resonance (MR) techniques are well suited for this purpose. We r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 50 9  شماره 

صفحات  -

تاریخ انتشار 2009