Micromethod for lead determination in whole blood by atomic absorption, with use of the graphite furnace.
نویسنده
چکیده
I describe a micro-scale method for determining lead in whole blood by utilizing a graphite furnace. Sample pretreatment consists of fivefold dilution with a dilute surfactant. The method is directly calibrated with lead standards prepared in dilute HNO3. To eliminate a small, nonspecific absorption signal from the blood matrix, simultaneous background correction is used. Interlaboratory comparison with a flame atomic absorption technique that requires extraction yielded high correlation (r equal to 0.98). Within-run precision (coefficient of variation) ranged from 2 to 4 percent. Lead in blood can be accurately measured in as little as 20 mul of blood, hence the method is suitable for routine laboratory use and for pediatric screening.
منابع مشابه
GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRY WITH MAlIlRIX MODIFICATION FOR DETERMINATION OF LEAD IN DRINKING WATER
An amoniumvanadate plus sodium molybdate mixed modifier Graphite Furnace Atomic Absorption Spectrometric method has been developed for determination of traces of lead in drinking water. The concentration of lead in the sample is obtained by direct comparison to linear working graph prepared from aqueous standards in the modifier medium, The results indicate the better performance of the pro...
متن کاملUtilization of electrodeposition on a graphite probe modified with palladium in determination of lead by graphite furnace atomic absorption spectrometry in water and environmental samples
In this work a rapid and selective procedure for separation and preconcentration of lead(Pb2+) before determination by electrothermal atomic absorption spectrometry (ETAAS) wasdeveloped. The procedure is based on the electrodeposition on a graphite probe modified withpalladium. The lead was deposited from acetate buffer solution at pH 5.5. Various parameters,such as pH of solutions, deposition ...
متن کاملAir-assisted Liquid Liquid Microextraction Combined with Graphite Furnace Atomic Absorption Spectrometry for Preconcentration and Determination of Trace Amount of Co(II) and Ni(II) Ions in Water Samples
A simple, rapid and efficient method has been developed for the extraction, preconcentration and determination of cobalt (II) and nickel (II) ions in water samples by air-assisted liquid-liquid microextraction (AALLME) coupled with graphite furnace atomic absorption spectrometry (GFAAS). In the proposed method, much less volume of an organic solvent was used as the extraction solvent in the abs...
متن کاملRapid ultramicro direct determination of erythrocyte lead concentration by atomic absorption spectrophotometry, with use of a graphite-tube furnace.
We describe a convenient, sensitive, accurate, precise and direct method for lead analysis in blood by use of the graphite-tube furnace with an atomic absorption spectrophotometer. Advantages of this proposed method are the ultramicro sample size and the minimal sample preparation required. Interferences by the major cations and anions in blood were studied and minimized. Anticoagulants examine...
متن کاملImproved sample preparation for accurate determination of low concentrations of lead in whole blood by graphite furnace analysis.
The effect of low concentrations of lead on pre- and post-natal growth and development is a current concern. We describe a simple method of sample preparation for direct determination of lead in whole blood by Zeeman graphite-furnace atomic absorption spectrometry. This procedure improves analytical precision and accuracy of lead determinations at low concentrations as compared with published f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 21 4 شماره
صفحات -
تاریخ انتشار 1975