Quantification of left ventricular volumes using three-dimensional echocardiographic speckle tracking: comparison with MRI.

نویسندگان

  • Hans-Joachim Nesser
  • Victor Mor-Avi
  • Willem Gorissen
  • Lynn Weinert
  • Regina Steringer-Mascherbauer
  • Johannes Niel
  • Lissa Sugeng
  • Roberto M Lang
چکیده

AIMS Although the utility of two-dimensional (2D) speckle tracking echocardiography (STE) to quantify left ventricular (LV) volume has been demonstrated, this methodology is limited by foreshortened views, geometric modelling, and the assumption that speckles can be tracked from frame to frame, despite their out of plane motion. To circumvent these limitations, a three-dimensional (3D) speckle tracking algorithm was recently developed. Our goal was to evaluate the accuracy of the new 3D-STE side by side with 2D-STE using cardiac magnetic resonance (CMR) as a reference. METHODS AND RESULTS Apical two- and four-chamber views (A2C and A4C) and real-time 3D datasets (Toshiba Artida 4D System) obtained in 43 patients with a wide range of LV size and function were analysed to measure LV end-systolic and end-diastolic volumes (ESV and EDV) using 2D and 3D-STE techniques. Short-axis CMR images (Siemens 1.5T scanner) acquired on the same day were analysed to obtain ESV and EDV reference values using the method of disks approximation. Reproducibility of both STE techniques was assessed using repeated measurements. While 2D-STE correlated well with CMR (r: 0.72-0.88), it underestimated LV volumes with relatively large biases (10-30 mL) and wide limits of agreement (SD: 36-51 mL), with A2C-derived measurements being worse than A4C values. The 3D-STE measurements showed higher correlation with CMR (0.87-0.92), and importantly smaller biases (1-16 mL) and narrower limits of agreement (SD: 28-37 mL). In addition, 3D-STE showed lower inter- and intra-observer variability (11-14% and 12-13%), than 2D-STE (16-17% and 12-16%, respectively). CONCLUSION This is the first study to validate the new 3D-STE technique for LV volume measurements and demonstrate its superior accuracy and reproducibility over previously used 2D-STE technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of strain and strain rate parameters using two-dimensional speckle-tracking echocardiography in patients with coronary artery disease (Research Article)

The study aimed was to measure left ventricular (LV) strain using speckle tracking echocardiography (STE) for assessment of LV function. Eighty-two subjects (mean age 57±9 years) with suspected chest pain underwent two-dimensional (2D)-echocardiography before coronary angiography. Conventional echocardiographic parameters were used for the assessment of LV function. Longitudinal strain and its ...

متن کامل

Comparison between three-dimensional speckle-tracking echocardiography and cardiac magnetic resonance imaging for quantification of left ventricular volumes and function.

AIMS We evaluated the accuracy of three-dimensional speckle-tracking echocardiography (3DSTE) to evaluate left ventricular (LV) volumes, ejection fraction (EF), and global circumferential strain (CS) in comparison with cardiac magnetic resonance imaging (MRI) in a healthy population. METHODS AND RESULTS A total of 45 out of 50 consecutive healthy subjects (38 males, age 45 ± 15 years) success...

متن کامل

Function and mechanics of the left ventricle: from tissue Doppler imaging to three dimensional speckle tracking.

One of the most common indications in echocardiography is the evaluation of left ventricular function. The traditional measurement of ejection fraction is based upon tracing the left ventricular borders and calculating left ventricular volumes using geometric assumptions. Now, with the introduction of three-dimensional echocardiography, the evaluation of left ventricular function is easier to c...

متن کامل

Comparison of left atrial function in healthy individuals versus patients with non-ST-segment elevation myocardial infarction using two-dimensional speckle tracking echocardiography

Left atrial (LA) function has been associated with adverse outcomes in patients after acute myocardial infarction. The purpose of the current study was to evaluate LA function in patients with non-ST-segment elevation myocardial infarction (NSTEMI) by two-dimensional speckle tracking echocardiography (2D STE). Fifty-one patients with NSTEMI and 40 age-matched normal control individuals were enr...

متن کامل

Volumetric and functional assessment of a left ventricular aneurysm from a single acquisition by three-dimensional speckle-tracking echocardiography (from the MAGYAR-Path Study).

Three-dimensional speckle-tracking echocardiography (3DSTE) is accepted as a reliable and feasible method in the quantification of left ventricular (LV) volumes, strains and rotational characteristics. This case aimed to demonstrate the diagnostic importance of 3DSTE in volumetric and functional assessment of an LV aneurysm.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European heart journal

دوره 30 13  شماره 

صفحات  -

تاریخ انتشار 2009