A Novel Method (CiMON) for Continuous Intra-Abdominal Pressure Monitoring: Pilot Test in a Pig Model
نویسندگان
چکیده
Background. Intravesical pressure (IAP(ivp)) measurement is considered to be the gold standard for assessment of intra-abdominal pressure (IAP). This study evaluated a new minimally invasive IAP monitoring device (CiMON) against three other devices in a wide range of clinically relevant IAP and in different body positions in healthy pigs. Methods. The CiMON catheter (IAP(CiM)) and another balloon-tipped catheter (IAP(spie)) were positioned into the stomach. Fluid-filled catheters were used for direct intraperitoneal (IAP(dir)) and IAP(ivp) measurement. Both in supine and 25° head-of-bed positions, IAP was increased from baseline to 30 mmHg. At every IAP level, 4 IAP measurements were recorded simultaneously. Mean differences and the limits of agreement were calculated. Results. Bias between IAP(CiM) and IAP(spie) was nearly zero with very good agreement, both in supine and 25° position. In supine position, IAP(CiM) slightly overestimated IAP(ivp) and IAP(dir) by 1.5 and 2.1 mmHg with reasonable agreement. In 25° position, IAP(CiM) underestimated IAP(ivp) and IAP(dir) by 1.0 and 0.5 mmHg, again with reasonable agreement. Conclusions. Agreement between IAP(CiM) and IAP(spie) was very good, while good-to-moderate agreement exists between IAP(CiM) and IAP(dir) or IAP(ivp). Simplicity, continuous monitoring, and the combination with a feeding tube should lead to further clinical studies, evaluating this new CiMON device.
منابع مشابه
Blood oxygenation during hyperpressure intraperitoneal fluid administration in a rabbit model of severe liver injury: Evaluation of a novel concept for control of pre-hospital liver bleeding
Oxygen is an essential part of the most important metabolic pathways in aerobic organisms. Oxygen delivery is merely dependent on blood, rendering blood loss a devastating event. Traumatic pre-hospital liver bleeding is a major cause of early trauma deaths in human and animals, with no established therapeutic method yet. Increasing intra-abdominal pressure (IAP) has been shown to reduce liver b...
متن کاملIntra-abdominal pressure and associated factors in patients admitted to critical care units
Introduction: Despite the impact of increased abdominal hypertension on organ dysfunction and ‎increased mortality, data on the frequency and its related risk factors in critical care unit does not ‎seem enough. While studies have shown that patients’ intra-abdominal pressure measured at ‎admission to intensive care unit can serve as an independent prognostic factor for mortal...
متن کاملIntegration of inspiratory and expiratory intra-abdominal pressure: a novel concept looking at mean intra-abdominal pressure
BACKGROUND The intra-abdominal pressure (IAP) is an important clinical parameter that can significantly change during respiration. Currently, IAP is recorded at end-expiration (IAPee), while continuous IAP changes during respiration (ΔIAP) are ignored. Herein, a novel concept of considering continuous IAP changes during respiration is presented. METHODS Based on the geometric mean of the IAP ...
متن کاملCommonly applied positive end-expiratory pressures do not prevent functional residual capacity decline in the setting of intra-abdominal hypertension: a pig model
INTRODUCTION Intra-abdominal hypertension is common in critically ill patients and is associated with increased morbidity and mortality. The optimal ventilation strategy remains unclear in these patients. We examined the effect of positive end-expiratory pressures (PEEP) on functional residual capacity (FRC) and oxygen delivery in a pig model of intra-abdominal hypertension. METHODS Thirteen ...
متن کاملComparison of Intra-abdominal Pressure Measurement and Physical Exam for Diagnosis of Surgery Indication in Patients with Abdominal Compartment Syndrome due to Blunt Trauma
Background & Aims: Increase in abdominal pressure can lead to the so-called intra–abdominal compartment syndrome (ACS) that is often observed during the first 24 hours after sever abdominal trauma and surgery. Measurement of the intra abdominal pressure through the bladder as a non-invasive measurement can provide a quick and accurate assessment of abdominal pressure changes. This study was per...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2012 شماره
صفحات -
تاریخ انتشار 2012